1990
DOI: 10.1088/0022-3727/23/8/008
|View full text |Cite
|
Sign up to set email alerts
|

Measurements of DT/μ of Na+ions in argon and neon

Abstract: Room temperature measurements of the ratio & / p between the transverse diffusion coefficient and the mobility of mass-identified ions in a neutral gas are reported for Na+ ions in argon and neon. A new apparatus was used which, in contrast to previous methods, does not involve mechanical movement which alters the geometry of the drift tube assembly during a measurement scan, or variation of the experimental conditions inside it. Results with an estimated accuracy of better than 3% were obtained at E/N values … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
10
0

Year Published

1991
1991
2003
2003

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 22 publications
(10 citation statements)
references
References 20 publications
(10 reference statements)
0
10
0
Order By: Relevance
“…This discrepancy is probably caused by a systematic error in the mobility measurements made with the Georgia Tech drift tube-mass spectrometer. 8,10,11 Considering the limits of the standard error for each set of data, there are generally good agreement among the four sets of D T (r) values. Excellent agreement between the experimental D T (r) values and the MCS calculated data in the low E/N region suggests that the KMV potential is a good representation of the actual potential in this region.…”
Section: Discussionmentioning
confidence: 78%
See 1 more Smart Citation
“…This discrepancy is probably caused by a systematic error in the mobility measurements made with the Georgia Tech drift tube-mass spectrometer. 8,10,11 Considering the limits of the standard error for each set of data, there are generally good agreement among the four sets of D T (r) values. Excellent agreement between the experimental D T (r) values and the MCS calculated data in the low E/N region suggests that the KMV potential is a good representation of the actual potential in this region.…”
Section: Discussionmentioning
confidence: 78%
“…[1][2][3][4][5][6][7] However, there is a dearth of experimental data for D T or D T /K of sufficient accuracy. [3][4][5][6][7][8][9][10][11][12][13][14][15] The only experimental data reported for both Rb ϩ -Kr and Rb ϩ -Xe systems are values of the reduced mobility ͑K 0 ͒, 16 and the product of the neutral gas number density and longitudinal diffusion coefficient ͑ND L ͒. 17 These data were compiled in numerical form by Ellis et al 18 To our knowledge, no transverse diffusion data has yet been reported for Rb ϩ ions drifting in Kr and Xe gases.…”
Section: Introductionmentioning
confidence: 99%
“…The variance x 2 , and the D T /K ratio for a given E/N value and drift length z were then derived from an analysis of the transverse ion current profile recorded. The experimental values of D T /K were temperature-corrected to 303 K using a formula given previously [9].…”
Section: The Experimental Methodsmentioning
confidence: 99%
“…Routine checks were duly made of the independence of the data from gas pressure, ion injection conditions and space charge effects. For the present ion-neutral gas pairs, the longitudinal end effects were found to be inevitably present but were effectively corrected for by using the technique reported earlier [10].…”
Section: The Experimental Methodsmentioning
confidence: 99%
“…Details of the apparatus used to measure Dr/K for K+and Na+-ion swarms in several rare gases have been previously reported [19,20]. Briefly, the method consists of allowing a low-density slit source to introduce ions at one end of a drift tube pressurized with a selected neutral gas.…”
Section: Measurements Of Dt /Kmentioning
confidence: 99%