2002
DOI: 10.1016/s1352-2310(02)00170-x
|View full text |Cite
|
Sign up to set email alerts
|

Measurements of atmospheric nitrous acid and nitric acid

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

12
89
4

Year Published

2002
2002
2020
2020

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 106 publications
(105 citation statements)
references
References 27 publications
12
89
4
Order By: Relevance
“…Losses may have occurred along the walls of the inlet sample air tubing and any water droplets accumulated in the inlet line may have caused further losses. Furthermore, comparison of nitric acid measurements made at other locations to this study indicated that the GPIC concentrations were lower than those typically observed (Hering et al, 1988;Boring et al, 2002;Huang et al, 2002;Fischer et al, 2006;Lin et al, 2006;Morino et al, 2006;Ullah et al, 2006).…”
Section: Gpic Comparison With Naps Denuder Measurementssupporting
confidence: 49%
“…Losses may have occurred along the walls of the inlet sample air tubing and any water droplets accumulated in the inlet line may have caused further losses. Furthermore, comparison of nitric acid measurements made at other locations to this study indicated that the GPIC concentrations were lower than those typically observed (Hering et al, 1988;Boring et al, 2002;Huang et al, 2002;Fischer et al, 2006;Lin et al, 2006;Morino et al, 2006;Ullah et al, 2006).…”
Section: Gpic Comparison With Naps Denuder Measurementssupporting
confidence: 49%
“…Detailed descriptions of the sampling site are given in Carroll et al [2001]. A 2-channel HONO measurement system [Zhou et al, 1999;Huang et al, 2002] was deployed. The method was based on aqueous-phase scrubbing of HONO using a coil sampler, followed by derivatization of scrubbed nitrite into a highly light-absorbing azo dye and HPLC analysis of the derivative with a UV-Vis detector.…”
Section: Methodsmentioning
confidence: 99%
“…Aerosols greater than 1 μm have been reported not to transmit as effectively through some systems [Huang et al, 2002], with a greater fraction of the total undergoing collection in the HONO (g) measurement channel as particle size increases. Interferences in field observations have been reported for fog events, where partitioned HONO (g) was credited with producing an artifact signal [Sörgel et al, 2011a].…”
Section: Intercomparison Of Hono (G) Measurements Between Aim-ic and mentioning
confidence: 99%