2010
DOI: 10.1016/j.atmosenv.2010.05.008
|View full text |Cite
|
Sign up to set email alerts
|

Measurements of aerosol optical properties in central Tokyo during summertime using cavity ring-down spectroscopy: Comparison with conventional techniques

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
33
0

Year Published

2011
2011
2023
2023

Publication Types

Select...
6
1

Relationship

3
4

Authors

Journals

citations
Cited by 30 publications
(33 citation statements)
references
References 40 publications
0
33
0
Order By: Relevance
“…The experimental system used in this work consists of the same components as the majority of those to be found in the literature (Bulatov et al 2002(Bulatov et al , 2006Riziq et al 2007;Beaver et al 2008Beaver et al , 2010Dinar et al 2008;Freedman et al 2009;Lang-Yona et al 2009Radney et al 2009;Adler et al 2010;Nakayama et al 2010) and has been described in detail in previous publications (Miles et al 2010a(Miles et al , 2010b. Briefly, particles were generated from an aqueous suspension/solution of the aerosol medium (polystyrene beads or sodium chloride) using a constant output atomizer (TSI Model 3076), before being passed through a Nafion dryer (Perma Pure PD-100T-12SS, http://www.permapure.com/) to remove residual water.…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations
“…The experimental system used in this work consists of the same components as the majority of those to be found in the literature (Bulatov et al 2002(Bulatov et al , 2006Riziq et al 2007;Beaver et al 2008Beaver et al , 2010Dinar et al 2008;Freedman et al 2009;Lang-Yona et al 2009Radney et al 2009;Adler et al 2010;Nakayama et al 2010) and has been described in detail in previous publications (Miles et al 2010a(Miles et al , 2010b. Briefly, particles were generated from an aqueous suspension/solution of the aerosol medium (polystyrene beads or sodium chloride) using a constant output atomizer (TSI Model 3076), before being passed through a Nafion dryer (Perma Pure PD-100T-12SS, http://www.permapure.com/) to remove residual water.…”
Section: Methodsmentioning
confidence: 99%
“…This highlights an important issue often neglected in publication of A-CRDS data, where the length of the cavity physically occupied by aerosol is frequently either omitted or stated without any reference as to whether it has been confirmed experimentally (Bulatov et al 2006;Garland et al 2007;Beaver et al 2008Beaver et al , 2010Thompson et al 2008;Freedman et al 2009;Baynard et al 2007;Riziq et al 2007;Spindler et al 2007;Dinar et al 2008;Riziq et al 2008;Khalizov et al 2009;Radney et al 2009;Xue et al 2009;Nakayama et al 2010). As the above discussion clearly shows, any uncertainty in the length of the cavity occupied by aerosol has a large impact on the values of the extinction efficiency retrieved by experiment and consequently on the refractive index returned by the fitting process.…”
Section: Uncertainty In the Length Of The Aerosol Sample Within The Cmentioning
confidence: 99%
See 2 more Smart Citations
“…The b sca (532 nm) data obtained by the PASS-3 was not used in this study because a strong particle size dependence of the calibration factors was found. A detailed description of the CRDS and PASS-3 has been previously reported (Nakayama et al 2010a(Nakayama et al , 2010b(Nakayama et al , 2012. The chemical properties of the aerosols were also measured using a high resolution time-of-flight aerosol mass spectrometer (Aerodyne Research, H-ToF-AMS) in the V-mode (Drewnick et al 2005).…”
Section: Wavelength Dependence Of Refractive Index Of Secondary Organmentioning
confidence: 99%