2023
DOI: 10.3390/s23062900
|View full text |Cite
|
Sign up to set email alerts
|

Measurement Uncertainty in Clinical Validation Studies of Sensors

Abstract: Accurate clinical sensors and devices are essential to support optimal medical decision-making, and accuracy can be demonstrated through the conduct of clinical validation studies using validated reference sensors and/or devices for comparison. Typically unmeasurable, the true reference value can be substituted with an accepted physiological measurement with an associated uncertainty. We describe a basic model of measurement uncertainty that specifies the factors that may degrade the accuracy of an observed me… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
0
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(5 citation statements)
references
References 5 publications
0
0
0
Order By: Relevance
“…ICC values have previously been defined as the following: less than 0.2—slight repeatability, between 0.2 and 0.4—low repeatability, between 0.4 and 0.7—moderate repeatability, between 0.7 and 0.9—high repeatability, and greater than 0.9—very high repeatability. 24 Using this scale, this study showed that repeatability increased from low to moderate when using 35 seconds of data versus a shorter time frame. A further increase in high repeatability occurred when only high-quality data were used to calculate the median reported SpO2.…”
Section: Discussionmentioning
confidence: 87%
See 4 more Smart Citations
“…ICC values have previously been defined as the following: less than 0.2—slight repeatability, between 0.2 and 0.4—low repeatability, between 0.4 and 0.7—moderate repeatability, between 0.7 and 0.9—high repeatability, and greater than 0.9—very high repeatability. 24 Using this scale, this study showed that repeatability increased from low to moderate when using 35 seconds of data versus a shorter time frame. A further increase in high repeatability occurred when only high-quality data were used to calculate the median reported SpO2.…”
Section: Discussionmentioning
confidence: 87%
“…These factors include the short-term variation within the patient (within-subject variation), the variations in how observers perform the measurement (within- and between-observer variation), and other variations in filtering, averaging, or rounding of measurements. 24 …”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations