2000
DOI: 10.1006/abbi.1999.1610
|View full text |Cite
|
Sign up to set email alerts
|

Measurement of the Main Photooxidation Products of 2′-Deoxyguanosine Using Chromatographic Methods Coupled to Mass Spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
41
0

Year Published

2001
2001
2017
2017

Publication Types

Select...
7
2

Relationship

3
6

Authors

Journals

citations
Cited by 55 publications
(42 citation statements)
references
References 24 publications
1
41
0
Order By: Relevance
“…The fluorescence detector was calibrated externally using the samples prepared by the derivatization of known quantities of the authentic guanidine hydrochloride; the amounts of oxazolone in the irradiated oligonucleotides were calculated from these calibration curves. The accuracy of this method for the quantitation of the Z lesions was confirmed by an HPLC-MS/MS assay (21).…”
Section: Methodsmentioning
confidence: 93%
See 1 more Smart Citation
“…The fluorescence detector was calibrated externally using the samples prepared by the derivatization of known quantities of the authentic guanidine hydrochloride; the amounts of oxazolone in the irradiated oligonucleotides were calculated from these calibration curves. The accuracy of this method for the quantitation of the Z lesions was confirmed by an HPLC-MS/MS assay (21).…”
Section: Methodsmentioning
confidence: 93%
“…The latter lesions were converted to the more stable Z lesions by storage of the irradiated samples in the dark at room temperature for ϳ48 h (18) and were detected by a post-fluorescence HPLC method (20). The accuracy of this method for the quantitation of the Z lesions in DNA was confirmed by the HPLC-MS/MS assay (21). The depletion of guanine and formation of 8-oxoGua lesions was assayed by reversed-phase HPLC methods after enzymatic digestion of the irradiated samples.…”
Section: Dynamics Of Guanine Lesion Formation-the Combination Of the mentioning
confidence: 99%
“…Collected fractions containing 4 were dissolved in water, and a UV absorption spectrum was recorded by using a Hewlett-Packard (Les Ullis, France) model 8453 apparatus. The molecular absorption coefficient, which is identical for at least isomers 4c and 4d, was determined by using 1 H NMR as described (42) …”
Section: Methodsmentioning
confidence: 99%
“…The total eluent was directed to the turbo ion spray source. Chlorinated nucleosides were detected using electrospray ionization tandem mass spectrometry in the multiple reaction monitoring mode (22,23). Specific transitions used to detect chlorinated nucleosides in the positive ionization mode were those between the molecular cation of the chlorinated nucleosides and the characteristic chlorinated daughter ion formed from the loss of the sugar moiety: 8-Cl-Guo, m/z 318 3 186; 8-Cl-dGuo, m/z 302 3 186; 8-Cl-Ado, m/z 302 3 170; 8-Cl-dAdo, m/z 286 3 170; 5-Cl-Cyd, m/z 278 3 146, and 5-Cl-dCyd, m/z 262 3 146.…”
Section: Methodsmentioning
confidence: 99%