Measurement of the deposition of fine sediments in a channel bed

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
11
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
7

Relationship

4
3

Authors

Journals

citations
Cited by 9 publications
(11 citation statements)
references
References 28 publications
0
11
0
Order By: Relevance
“…Three different grain sizes were used, d 50 = 200 μm (for the uniform grain size tests) and d 50 = 160 and 80 μm (for the sediment mixtures tests). The three grain sizes had the same sediments characteristics, namely, a density of 1,160 kg/m 3 , a coefficient of uniformity (i.e., D 60 /D 10 , where the D 60 and D 10 are the diameters corresponding to 60% and 10% finer in the particle-size distribution) of 1.1 and an irregular shape (checked with an optical microscope, see Chamoun et al, 2016). The mean diameter was chosen to be in the range of noncohesive fine sediment, 62-500 μm, according to Van Rijn (2007).…”
Section: Experimental Designmentioning
confidence: 99%
“…Three different grain sizes were used, d 50 = 200 μm (for the uniform grain size tests) and d 50 = 160 and 80 μm (for the sediment mixtures tests). The three grain sizes had the same sediments characteristics, namely, a density of 1,160 kg/m 3 , a coefficient of uniformity (i.e., D 60 /D 10 , where the D 60 and D 10 are the diameters corresponding to 60% and 10% finer in the particle-size distribution) of 1.1 and an irregular shape (checked with an optical microscope, see Chamoun et al, 2016). The mean diameter was chosen to be in the range of noncohesive fine sediment, 62-500 μm, according to Van Rijn (2007).…”
Section: Experimental Designmentioning
confidence: 99%
“…Note that only some of the bottom deposition electrodes are shown. They are placed throughout the flume starting 10-620 cm from the inlet and separated by 10 cm (Chamoun et al 2016c;Oehy 2003).…”
Section: Measurementsmentioning
confidence: 99%
“…De Rooij et al (1999), Oehy (2003) and Chamoun et al (2016c). Deposition is measured in space and time at 62 fixed points of the main flume.…”
Section: Experimental Measurementsmentioning
confidence: 99%
“…Deposition is measured in space and time at 62 fixed points of the main flume. An error analysis (Chamoun et al, 2016c) showed that the total error that can affect the measured thickness of the deposit is around 0.06 mm (zd 10 ). -Temperatures are measured in the head tank and in the main flume before and after the tests for two main reasons: (1) during the tests, these two temperatures should be close enough to keep the density difference solely due to the presence of suspended particles.…”
Section: Experimental Measurementsmentioning
confidence: 99%