Measurement of rigidity in Parkinson's disease

Abstract: Clinical assessment of rigidity in parkinsonian patients is largely qualitative. The reliability and validity of the assessments are sometimes in doubt. Several "engineering" methods of quantifying rigidity have been described, but none has been adopted into general clinical practice. A possible reason is that these methods differ in crucial aspects from the clinical exam. We therefore tackled the problem by monitoring the clinical exam itself, using small sensors to measure the forces and displacements applie… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
98
0
2

Year Published

1999
1999
2008
2008

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 122 publications
(102 citation statements)
references
References 28 publications
(24 reference statements)
1
98
0
2
Order By: Relevance
“…However, these previous reports relied on clinical rigidity rating scales and did not employ objective, quantitative measures of rigidity. We measured rigidity using a validated analog scale (rigidity analyzer) that was demonstrated to be more sensitive and more reproducible than the rank-order scale widely used in clinical practice and studies (UPDRS) (Prochazka et al, 1997). In that validation study, under different testing conditions (such as on and off medication), mean UPDRS-rigidity ratings (R) of 4 experienced raters were plotted against the corresponding mean impedance measurements (Z) obtained using a rigidity analyzer in 7 PD patients with a wide range of rigidity severity.…”
Section: Control Of Rigiditymentioning
confidence: 99%
See 1 more Smart Citation
“…However, these previous reports relied on clinical rigidity rating scales and did not employ objective, quantitative measures of rigidity. We measured rigidity using a validated analog scale (rigidity analyzer) that was demonstrated to be more sensitive and more reproducible than the rank-order scale widely used in clinical practice and studies (UPDRS) (Prochazka et al, 1997). In that validation study, under different testing conditions (such as on and off medication), mean UPDRS-rigidity ratings (R) of 4 experienced raters were plotted against the corresponding mean impedance measurements (Z) obtained using a rigidity analyzer in 7 PD patients with a wide range of rigidity severity.…”
Section: Control Of Rigiditymentioning
confidence: 99%
“…The validity and reliability of the device and its use in measuring parkinsonian rigidity have been described (Patrick et al, 2001;Prochazka et al, 1997). Briefly, the device consists of an inflatable cuff force transducer and a gyro-based velocity sensor.…”
Section: Quantitative Measures Of Motor Behavior Rigiditymentioning
confidence: 99%
“…This should complete the clinical picture obtained by using devices where stiffness is only evaluated in terms of rigidity, i.e. resistance to motion performed by the examiner (Ghika et al 1993;Caligiuri, 1994;Prochazka et al 1997). However, further experiments combining mechanical and neurophysiological approaches are needed to improve knowledge of the predominant behaviour of passive and active structures that leads to the functional consequences observed in DMD.…”
Section: Stiffness Indices and Muscle Weaknessmentioning
confidence: 99%
“…Another factor is the stretch velocity of imposed movement. In previous studies, the stretch movement was limited to relatively slow stretch velocity such that the acceleration/deceleration effects on the resistance were usually ignored [4]. However, higher stretching velocity is generally required, especially for observing velocity-dependent tests, such as the spasticity measurement.…”
Section: Discussionmentioning
confidence: 99%
“…In laboratory environment, m otor-driven systems which stretch the paretic limbs with various stretching modes for quantifying muscle tone have been developed [1][2] [3]. However, researchers have criticized the motor-driven systems are too cumbersome and inconvenient in clinical test environment [4]. Compared to motor-driven systems, hand-held systems seem to have advantages in providing an on-line quantification of muscle tone, especially in clinical routine examination or in surgical room.…”
Section: Introductionmentioning
confidence: 99%