2017
DOI: 10.1016/j.psep.2016.04.026
|View full text |Cite
|
Sign up to set email alerts
|

Measurement of pollution levels of N-nitroso compounds of health concern in water using ultra-performance liquid chromatography–tandem mass spectrometry

Abstract: International audienceThis paper reports the development of a highly sensitive analytical method combining solid-phase extraction (SPE) with ultra-high performance liquid chromatography coupled with tandem mass spectrometry (UHPLC–MS/MS), for the monitoring of ultra-trace levels of N-nitrosamines in water samples. Under optimized analytical conditions, chromatographic separation was performed in 3 min, in isocratic mode, using an Acquity UHPLC C18 column and a mobile phase consisting of acetonitrile, water, an… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 11 publications
(6 citation statements)
references
References 45 publications
(36 reference statements)
0
6
0
Order By: Relevance
“…Under these conditions the retention time of CLA was 14 minutes and the instrumental limit of quantification (LOQ) was lower than 0.05 mg L -1 . CLA concentration (expressed in mg L -1 ) was calculated using an external calibration curve, as previously described by Kadmi et al (2017). Calibration was performed in the range of 0-10 mg L -1 by the use of standard solutions with a known analyte concentration.…”
Section: Hplc Analysismentioning
confidence: 99%
“…Under these conditions the retention time of CLA was 14 minutes and the instrumental limit of quantification (LOQ) was lower than 0.05 mg L -1 . CLA concentration (expressed in mg L -1 ) was calculated using an external calibration curve, as previously described by Kadmi et al (2017). Calibration was performed in the range of 0-10 mg L -1 by the use of standard solutions with a known analyte concentration.…”
Section: Hplc Analysismentioning
confidence: 99%
“…CPX (50 mg/L) solutions with different pH (2)(3)(4)(5)(6)(7)(8)(9)(10)(11)(12) were put in contact with 1 g of biosorbent beads. Once the favorable pH value was established, the amount of the biosorbent was varied (0.5-3 g).…”
Section: Effect Of Biosorption Parameters (Ph Biosorbent Amount Cpx Initial Concentration)mentioning
confidence: 99%
“…Pollution of the environment by pharmaceuticals is a challenging issue [ 1 , 2 , 3 , 4 , 5 ]. In fact, the development of analytical techniques has allowed their quantification in different environmental matrices [ 6 , 7 ].…”
Section: Introductionmentioning
confidence: 99%
“…Freshly prepared standard solutions were used for this purpose. The instrumental limit of detection for clofibric acid was estimated according to the procedure described by Kadmi et al [33].…”
Section: Photocatalytic Activity Evaluationmentioning
confidence: 99%