1991
DOI: 10.1016/0003-2697(91)90520-4
|View full text |Cite
|
Sign up to set email alerts
|

Measurement of plasma acetate kinetics using high-performance liquid chromatography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
8
0

Year Published

1993
1993
2005
2005

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 15 publications
(8 citation statements)
references
References 16 publications
0
8
0
Order By: Relevance
“…As the level of formate in case 1 was six times higher than that in case 2, measuring formate in addition to methanol is considered to be useful in suspected methanol poisoning in order to elucidate the solution ingested. Acetate concentrations in both cases were within a control range (0.06 mM [34], 0.03 mM [35], 0.181 mM [32]). Therefore, formate poisoning was verified.…”
Section: Practical Applicationsmentioning
confidence: 84%
“…As the level of formate in case 1 was six times higher than that in case 2, measuring formate in addition to methanol is considered to be useful in suspected methanol poisoning in order to elucidate the solution ingested. Acetate concentrations in both cases were within a control range (0.06 mM [34], 0.03 mM [35], 0.181 mM [32]). Therefore, formate poisoning was verified.…”
Section: Practical Applicationsmentioning
confidence: 84%
“…p-Bromophenacyl ester derivatives of acetate and NAA were prepared using p-bromophenacylbromide and crown ether (a phase transfer catalyst) in acetonitrile (Durst et al, 1975;Persson et al, 1991). Briefly, 100 l of acetonitrile and 40 l of p-bromophenacylbromide reagent were added to the lyophilized tissue extract prepared as above in a microcentrifuge tube (each vial containing 200-l equivalent of the 20% tissue homogenate), and the vials were tightly capped.…”
Section: Methodsmentioning
confidence: 99%
“…To ensure fi-hydroxybutyrate has high UV absorption and enhanced liquid chromatographic characteristics, derivatization is applicable. A commercial reagent, bromoacetophenone, has been used to derivatize plasma acetate before HPLC analysis [16], but a very complicated extraction step including ether extraction, centrifugafion, and drying is required before derivafizafion, procedures which usually took approximately 5h. After this pretreatment derivatization of the residue with bromoacetophenone was also tedious and…”
Section: Introductionmentioning
confidence: 99%
“…Colorimetric [11], gas chromatographic (GC) [12][13][14][15], high-performance liquid chromatographic (HPLC) [16], and nuclear magnetic resonance spectroscopic [17,18] techniques have been introduced for measurement of fi-hydroxybutyrate concentrations. Head-space GC is the most widely used technique for analysis of fi-hydroxybutyrate in a variety of matrices.…”
Section: Introductionmentioning
confidence: 99%