“…For L 1 , the emission spectrum consisted of a very weak band, displaying significant vibrational structure, with a maximum at ca. 335 nm and a quantum yield of 0.047 ((5%) as determined by the optically dilute method 24 with reference to the parent naphthalene chromophore (Φ F ) 0.42). 25 Also evident in the emission spectrum of L 1 was a broad featureless band to lower energy centered at ca.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…For L 1 , the emission spectrum consisted of a very weak band, displaying significant vibrational structure, with a maximum at ca. 335 nm and a quantum yield of 0.047 ((5%) as determined by the optically dilute method 24 with reference to the parent naphthalene chromophore (Φ F ) 0.42). 25 Also evident in the emission spectrum of L 1 was a broad featureless band to lower energy centered at ca.…”
Section: Methodsmentioning
confidence: 99%
“…The fluorescence quantum yield was determined to be 0.006 ((5%) by comparison to the parent chromophore. 24 As with the naphthyl system, the [ Time-Resolved Photophysics. Time-resolved fluorescence decay profiles for L 1 and L 2 were measured by the TCSPC technique in CH 3 CN solution.…”
Section: Methodsmentioning
confidence: 99%
“…Quinine sulfate in 1.0 N sulfuric acid was used as the reference (Φ r = 0.546). 36 Luminescence lifetimes were determined with a HORIBA Jobin Yvon IBH FluoroLog-3 spectrofluorimeter, adapted for time resolved measurements. A sub-microsecond Xenon flash lamp (Jobin Yvon, 5000XeF) was used as the light source, coupled to a double grating excitation monochromator for spectral selection.…”
Section: Photophysicsmentioning
confidence: 99%
“…The Tb(III) complexes (10M) were prepared in situ in 0.1M Tris buffered H 2 O (pH 7.4) with 0.2% DMSO. Quantum yields were determined by the optically dilute method 49 reproduce experimental ligand triplet energies within ~5%. Together, the experimental and computational results serve as a predictive tool that can be used to guide antenna ligand design.…”
Section: -(Benzyloxy)-5-methoxy-n-methyl-3-(2-thioxothiazolidine-3-cmentioning