2008
DOI: 10.1016/j.ces.2007.11.003
|View full text |Cite
|
Sign up to set email alerts
|

Measurement of local specific interfacial area in bubble columns via a non-isokinetic withdrawal method coupled to electro-optical detector

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2009
2009
2018
2018

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 8 publications
(6 citation statements)
references
References 30 publications
0
6
0
Order By: Relevance
“…In this study, the five parameters used to correlate the separation performance of froth flotation are: average air bubble size diameter, Sauter mean diameter, air bubble surface area flux, air bubble number flux, and the specific surface area of air bubbles [19,[52][53][54][55][56][57]. All of these air bubble parameters need to be taken into consideration for the scale up of a froth flotation column, apart from basic process parameters such as surfactant concentration, air flow rate, and hydraulic retention time (HRT).…”
Section: Effect Of Surfactant On Air Bubble Characteristicsmentioning
confidence: 99%
See 2 more Smart Citations
“…In this study, the five parameters used to correlate the separation performance of froth flotation are: average air bubble size diameter, Sauter mean diameter, air bubble surface area flux, air bubble number flux, and the specific surface area of air bubbles [19,[52][53][54][55][56][57]. All of these air bubble parameters need to be taken into consideration for the scale up of a froth flotation column, apart from basic process parameters such as surfactant concentration, air flow rate, and hydraulic retention time (HRT).…”
Section: Effect Of Surfactant On Air Bubble Characteristicsmentioning
confidence: 99%
“…where d i is the equivalent spherical diameter (m) of air bubble i, and n is the number of bubbles [54,55].…”
Section: Effect Of Surfactant On Air Bubble Characteristicsmentioning
confidence: 99%
See 1 more Smart Citation
“…More recent work has used photography [23]- [25][44]- [47], nonisokinetic withdrawal in conjunction with electro-optic detection [48], two needle local probes [49], four fibre optic probes [50] and a Wire Mesh Sensor [21]. The liquids used were almost exclusively water with different chemical dissolved in them, e.g., Na2CO3, NaHCO3, NaOH [43], DEA [44], TEA [45], polymer plus surfactant [46] and surfactant [47].…”
Section: Figmentioning
confidence: 99%
“…Two of them [48,50] used water, the third [57] employed cyclohexane, a liquid with a surface tension much smaller than water and the fourth [51] used a silicone oil which has a low surface tension and a viscosity of 5 times that of water. These four are all from columns of diameter >100 mm and had distributors which were perforated plates with holes of small diameter, 0.5 mm [49,50,52,57].…”
Section: Other (Lower Viscosity)mentioning
confidence: 99%