2008
DOI: 10.12693/aphyspola.113.1629
|View full text |Cite
|
Sign up to set email alerts
|

Measurement of L Shell X-Ray Production and Average L Shell Fluorescence Yields for Some Heavy Elements at 123.6 keV

Abstract: L2γ, L2η, L 1β and L1γ X-ray production cross--sections and L shell average fluorescence yields were measured for the elements from Re to U using excitation energy of 123.6 keV. Measurements were performed using an 57 Co annular radioactive source and a Si(Li) detector. The theoretical values of the cross-sections were calculated using theoretically tabulated values of subshell photoionization cross-sections; the Coster-Kronig transition probabilities were based on the Dirac-HartreeSlater theory and radiative… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2009
2009
2019
2019

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 12 publications
(3 citation statements)
references
References 47 publications
(40 reference statements)
0
3
0
Order By: Relevance
“…Apaydın et al [11] calculated the L-shell average fluorescence yield and the production cross-section for the elements in the atomic range 75 6 Z 6 92 using a 57 Co radioactive source and a Si(Li) detector. Özdemir [12] measured the L sub-shell fluorescence and the Auger yields for the elements from Cs to U using a 241 Am radioactive source of strength 100 mCi and a Si(Li) detector.…”
Section: Introductionmentioning
confidence: 99%
“…Apaydın et al [11] calculated the L-shell average fluorescence yield and the production cross-section for the elements in the atomic range 75 6 Z 6 92 using a 57 Co radioactive source and a Si(Li) detector. Özdemir [12] measured the L sub-shell fluorescence and the Auger yields for the elements from Cs to U using a 241 Am radioactive source of strength 100 mCi and a Si(Li) detector.…”
Section: Introductionmentioning
confidence: 99%
“…The theoretically calculation of L shell X-ray cross-sections have been performed as explained in our earlier paper [26]. …”
Section: X-ray Fluorescence Analysismentioning
confidence: 99%
“…The fluorescence parameters of the K, L and M shells of the elements are used in scientific researches especially in nuclear power plants, radiation protection, storage of radioactive materials, space studies etc. Moreover, a comparison of the fluorescence parameters with theoretical estimates provides a check on the validity of various physical parameters in the evaluation of theoretical estimation [4]. When looked at the literature, the L X-ray intensity ratios of the samples have been studied by a number of researchers using different detectors and sources [5][6][7][8][9][10][11][12][13][14][15][16][17][18][19].…”
Section: Introductionmentioning
confidence: 99%