1999
DOI: 10.1016/s0378-4347(99)00367-9
|View full text |Cite
|
Sign up to set email alerts
|

Measurement of hydroxyl radical in rat blood vessel by microbore liquid chromatography and electrochemical detection: an on-line microdialysis study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
6
0

Year Published

2003
2003
2014
2014

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 24 publications
(6 citation statements)
references
References 25 publications
0
6
0
Order By: Relevance
“…There have been several applications of online MD -LC systems reported over the past decade by the Tsai group and others for the in vivo monitoring of drugs [112 -116] , neurotransmitters, neuropeptides, and other important biomolecules, including reactive oxygen species [117,118] . Applications included primarily pharmacokinetic, metabolism, and neurochemical studies.…”
Section: Off -Line Analysis Using Liquid Chromatographymentioning
confidence: 99%
“…There have been several applications of online MD -LC systems reported over the past decade by the Tsai group and others for the in vivo monitoring of drugs [112 -116] , neurotransmitters, neuropeptides, and other important biomolecules, including reactive oxygen species [117,118] . Applications included primarily pharmacokinetic, metabolism, and neurochemical studies.…”
Section: Off -Line Analysis Using Liquid Chromatographymentioning
confidence: 99%
“…For determination of nitric oxide metabolites (NO x ¡ ) or dihydroxybenzoic acid (DHBA), a microdialysis probe (CMA/20 20/40 PC; CMA/Microdialysis AB, Stockholm, Sweden) was put into jugular vein/right atrium as described previously (Tsai et al 1999). The NO x ¡ concentrations in the dialysates were measured with the Eicom ENO-20 NO x ¡ analysis system (Eicom, Kyoto) (Togashi et al 1998).…”
Section: Biochemical Determinationmentioning
confidence: 99%
“…doi:10.1016/j.jelechem.2005.01.002 Å OH without a derivation or trapping step [16]. Gas chromatography-mass spectrometry (GC-MS) [17] and high performance liquid chromatography with electrochemical detection (HPLC-ED) [18][19][20] are the most commonly used methods. In HPLC-ED methods, SA has been usually used as the trap to determine Å OH by measuring its hydroxylation products (2,3-dihydroxybenzoic acid, 2,3-DHBA, and 2,5-dihydroxybenzoic acid, 2,5-DHBA).…”
Section: Introductionmentioning
confidence: 99%