1991
DOI: 10.1016/0009-9120(91)90168-e
|View full text |Cite
|
Sign up to set email alerts
|

Measurement of cyclosporine a by a specific radioimmunoassay with a monoclonal antibody and 125I tracer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
3
0

Year Published

1992
1992
2005
2005

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 16 publications
(3 citation statements)
references
References 25 publications
0
3
0
Order By: Relevance
“…These clinical and experimental observations, as well as the idiosyncratic behavior of each patient, may suggest that Tac-based immunosuppression can decrease the frequency of CAN and that Tac use could be also beneficial for patients with documented CAN under CsA. Therefore, switching from CsA to Tac has been proposed as safe and effective in patients with CsA intolerance, nephrotoxicity, or ongoing rejection (15)(16)(17)(18)(19)(20)(21).…”
mentioning
confidence: 92%
“…These clinical and experimental observations, as well as the idiosyncratic behavior of each patient, may suggest that Tac-based immunosuppression can decrease the frequency of CAN and that Tac use could be also beneficial for patients with documented CAN under CsA. Therefore, switching from CsA to Tac has been proposed as safe and effective in patients with CsA intolerance, nephrotoxicity, or ongoing rejection (15)(16)(17)(18)(19)(20)(21).…”
mentioning
confidence: 92%
“…[92][93][94] There is a mean overestimate compared with HPLC of around 25% ( Although the CYCLO-Trac" SP kit uses the same monoclonal antibody as the original Sandimmunf-Kit, cross-reactivity with cyclosporin metabolites appears greater for the former assay, perhaps as a result of the different tracer or the secondary antibody precipitation step. Overestimation relative to HPLC is approximately twice that of the Sandimmun assay" and crossreactivity is greatest for metabolites AM9, AM4N and AMI, ranging from 2'2-15070, 1'7-4-4010 and 0·7 to 5'7070, respectively.Pv'"…”
Section: Min --mentioning
confidence: 99%
“…Analytical methods for cyclosporine in whole blood include high-performance liquid chromatography (HPLC), fluorescence polarization immunoassay (FPIA), radioimmunoassay (RIA), and enzyme-multiplied immunoassay technique (EMIT) (5)(6)(7)(8)(9). The HPLC method has the advantage of detecting only native cyclosporine and cyclosporine metabolites, but it usually involves time-consuming processes for analysis, and requires special equipment and maintenance.…”
Section: Introductionmentioning
confidence: 99%