1966
DOI: 10.1152/jappl.1966.21.3.1131
|View full text |Cite
|
Sign up to set email alerts
|

Measurement of cardiac output by thermal-dilution and direct Fick methods in dogs.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...

Citation Types

0
4
0

Year Published

1970
1970
2009
2009

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 36 publications
(4 citation statements)
references
References 0 publications
0
4
0
Order By: Relevance
“…; DYSON et al, 1985), dogs ( KHALIL et al, 1966;SANMARCO et al, 1971; GANZ and SWAN, 1972;WEISEL et al, 1975 a;MOODIE et al, 1978), lambs (KUIPERS et al, 1982), pigs (SORENSEN et a]., 1975; KUWAHARA et al, 1988), infants (WYSE et al, 1975CALLAGHAN et al, 1976), adult humans ( SLEEPER et al, 1962;BRANTHWAITE and BRADLEY, 1968;OLSSON et al, 1970;GANZ et al, 1971; GANZ and SWAN, 1972;WEISEL et al, 1975 b;BERGER et al, 1976;KOHANNA and CUNNINGHAM, 1977), and horses (FEGLER, 1954;MUIR et al, 1976).…”
mentioning
confidence: 99%
“…; DYSON et al, 1985), dogs ( KHALIL et al, 1966;SANMARCO et al, 1971; GANZ and SWAN, 1972;WEISEL et al, 1975 a;MOODIE et al, 1978), lambs (KUIPERS et al, 1982), pigs (SORENSEN et a]., 1975; KUWAHARA et al, 1988), infants (WYSE et al, 1975CALLAGHAN et al, 1976), adult humans ( SLEEPER et al, 1962;BRANTHWAITE and BRADLEY, 1968;OLSSON et al, 1970;GANZ et al, 1971; GANZ and SWAN, 1972;WEISEL et al, 1975 b;BERGER et al, 1976;KOHANNA and CUNNINGHAM, 1977), and horses (FEGLER, 1954;MUIR et al, 1976).…”
mentioning
confidence: 99%
“…The recording of the TD curve has been obtained in the pulmonary artery [3-6, 9, 23] or in a systemic artery [4-6, 9, 12, 13]. Others have used a constant infusion technique [19,22] or a constant heat addition to the blood for the measurement [15,16], Comparison between CO determination by TD and dye dilution (DD) have been reported [5. 6, 8, 9] as well as with the Fick method [3.…”
mentioning
confidence: 99%
“…The regression equation for 47 experiments was found to be COrd = 0.95 COnek + 0.08; the correlation coefficient was 0.94.The thermal dilution method for estimating cardiac output, introduced by Fegler (5), is commonly used both in man (2,8,17) and animals (10,14,15,20,21). The purpose of this study was to validate in dog experiments a method for thermal dilution measurement which employs a double-thermistor catheter combined with an automatic computer as described by 01sson et al Dilution and injectate temperature are entered directly into the calculation.…”
mentioning
confidence: 99%
“…The thermal dilution method for estimating cardiac output, introduced by Fegler (5), is commonly used both in man (2,8,17) and animals (10,14,15,20,21). Pulmonary detection and right atrial injection of indicator is usually preferred over other injection and detection sites (13, 24); proper mixing of the indicator over the short distance is achieved by the mechanical action of the right ventricle (22).…”
mentioning
confidence: 99%