2010
DOI: 10.1016/j.clinph.2009.10.017
|View full text |Cite
|
Sign up to set email alerts
|

Measurement of brain function in pre-school children using a custom sized whole-head MEG sensor array

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
52
0

Year Published

2010
2010
2020
2020

Publication Types

Select...
7
1

Relationship

4
4

Authors

Journals

citations
Cited by 75 publications
(53 citation statements)
references
References 19 publications
1
52
0
Order By: Relevance
“…Both systems were housed in the same magnetically shielded room (MSR, Fujihara Co. Ltd., Tokyo, Japan). Detailed descriptions and specification of this device are available in Johnson et al (2010) and He et al (2014).…”
Section: Data Acquisitionmentioning
confidence: 99%
See 1 more Smart Citation
“…Both systems were housed in the same magnetically shielded room (MSR, Fujihara Co. Ltd., Tokyo, Japan). Detailed descriptions and specification of this device are available in Johnson et al (2010) and He et al (2014).…”
Section: Data Acquisitionmentioning
confidence: 99%
“…The adult system (Model PQ1160R-N2, KIT, Kanazawa, Japan) consisted of 160 coaxial first-order gradiometers with a 50 mm baseline (Kado et al, 1999). The child system (Model PQ1064R-N2m, KIT, Kanazawa, Japan) consisted of 64 firstorder axial gradiometers with a 50 mm baseline (Johnson et al, 2010). Both systems were housed in the same magnetically shielded room (MSR, Fujihara Co. Ltd., Tokyo, Japan).…”
Section: Data Acquisitionmentioning
confidence: 99%
“…This is discussed more extensively in a later section. There have been attempts to develop smaller custom sized helmets [24,54], but these are not commonly available. However, the hope is that as more groups pursue developmental studies and highlight the need for new pediatric developments, this will spur commercial developments and industry to invest in developing hardware that is child-appropriate.…”
Section: Introductionmentioning
confidence: 99%
“…Child MEG system: Data acquisition is done using a whole-head child MEG system (KIT, Kanazawa, Japan) [2]. Data is acquired continuously at a sample rate of 1000Hz, with an online band pass filter between 0.03 Hz and 200Hz.…”
Section: Equipment Used During Data Acquisition and Experimental Taskmentioning
confidence: 99%
“…The KIT-Macquarie Brain Research Laboratory at Macquarie University uses a MEG system custom sized to fit the heads of pre-school children. This child system has 64 first-order axial gradiometers with a 50 mm baseline [2] and is contained inside a magnetically-shielded room (MSR) together with a conventional adult-sized MEG system [3,4]. There are three main advantages of the customized helmet dewar for studying children.…”
Section: Introductionmentioning
confidence: 99%