2012
DOI: 10.1063/1.4716030
|View full text |Cite
|
Sign up to set email alerts
|

Measurement of bonding energy in an anhydrous nitrogen atmosphere and its application to silicon direct bonding technology

Abstract: Bonding energy represents an important parameter for direct bonding applications as well as for the elaboration of physical mechanisms at bonding interfaces. Measurement of bonding energy using double cantilever beam (DCB) under prescribed displacement is the most used technique thanks to its simplicity. The measurements are typically done in standard atmosphere with relative humidity above 30%. Therefore, the obtained bonding energies are strongly impacted by the water stress corrosion at the bonding interfac… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
54
0

Year Published

2015
2015
2021
2021

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 64 publications
(55 citation statements)
references
References 31 publications
0
54
0
Order By: Relevance
“…• C. Noteworthy, as shown also in our previous work, 8 Lawn's WSC equation 2 of Zone II for instance can be applied on the direct bonding crack opening phenomenon. where η is the number of absorbed molecules per active site, a 0 the distance between two absorption sites, l the mean free path of water vapor, m the water molecule mass, p H20 the water partial pressure and E the Young's modulus.…”
Section: Direct Bonding Siloxane Bondsmentioning
confidence: 99%
See 3 more Smart Citations
“…• C. Noteworthy, as shown also in our previous work, 8 Lawn's WSC equation 2 of Zone II for instance can be applied on the direct bonding crack opening phenomenon. where η is the number of absorbed molecules per active site, a 0 the distance between two absorption sites, l the mean free path of water vapor, m the water molecule mass, p H20 the water partial pressure and E the Young's modulus.…”
Section: Direct Bonding Siloxane Bondsmentioning
confidence: 99%
“…In this study, we use the El-Zein's formula after having calculated the real bonding length using also El-Zein's beam equation. 8,27 After the adhesion energy measurement, the adherence or bonding energy could be measured simply by moving the blade inside the bonding to induce a classical debonded length.…”
Section: Direct Bonding Siloxane Bondsmentioning
confidence: 99%
See 2 more Smart Citations
“…After the blade insertion, we measured the debonded length (i.e., the crack propagation length, L) using the IR imaging system within 30 s to avoid the effects of humid atmosphere on the surface energy as much as possible. 17 Fig . 3a shows the IR image of the crack-opening method for full bonded wafer.…”
Section: Methodsmentioning
confidence: 99%