Measurement of Apparent Diffusion Coefficient (ADC) Values of Ependymoma and Medulloblastoma Tumors: a Patient-based Study

Abstract: Background: aimed to compare the apparent diffusion coefficient (ADC) of two different cerebellar pediatric tumors, including ependymoma and medulloblastoma which have shown similar clinical images in conventional magnetic resonance imaging (MRI) methods.Material and Methods: Thirty six pediatric patients who were suspected to have the mentioned tumors according to their CT image findings were included in this study. The patients were subjected to conventional MRI protocols followed by diffusion weighted imagi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

1
7
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(8 citation statements)
references
References 25 publications
1
7
0
Order By: Relevance
“…30 Six of the seven studies acquired DWI echo planar imaging (EPI) acquisitions. 21,27,[29][30][31][32] Of these six studies, repetition times ranged from 2435 to 8575 msec, echo times ranged from 60 to 161 msec, slices thickness ranged from 4 to 6 mm and slice gaps ranged from 0 to 3 mm. These six studies acquired b-values of 0 and 1000, with one study also acquiring an additional b-value of 500.…”
Section: Resultsmentioning
confidence: 99%
See 4 more Smart Citations
“…30 Six of the seven studies acquired DWI echo planar imaging (EPI) acquisitions. 21,27,[29][30][31][32] Of these six studies, repetition times ranged from 2435 to 8575 msec, echo times ranged from 60 to 161 msec, slices thickness ranged from 4 to 6 mm and slice gaps ranged from 0 to 3 mm. These six studies acquired b-values of 0 and 1000, with one study also acquiring an additional b-value of 500.…”
Section: Resultsmentioning
confidence: 99%
“…27 One study in the final cohort did not report any DWI parameters. 16 Three studies acquired data solely from Philips Achieva 1.5 T scanners, 16,21,32 one study acquired data solely from a Siemens 1.5 T scanner, 27 one study acquired data solely from a GE 1.5 T scanner, and two studies combined data from multiple scanners. 29,30 Only one study included the use of 3 T MRI scanners 30 and was also the only multi-institutional study (Table 2).…”
Section: Resultsmentioning
confidence: 99%