1976
DOI: 10.1016/0009-8981(76)90338-7
|View full text |Cite
|
Sign up to set email alerts
|

Measurement of angiotensin II in human plasma: Technical modifications and practical experience

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
66
0

Year Published

1981
1981
2006
2006

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 230 publications
(67 citation statements)
references
References 10 publications
1
66
0
Order By: Relevance
“…Blood samples for angiotensin II (AngII) levels were drawn in prechilled tubes after 30 min of supine rest and immediately centrifuged at 4°C. Plasma concentrations were measured radioimmunologically (12). Blood samples for renin concentration were taken after 30 min supine rest and measured directly by an improved immunoradiometric assay (13) …”
Section: Methodsmentioning
confidence: 99%
“…Blood samples for angiotensin II (AngII) levels were drawn in prechilled tubes after 30 min of supine rest and immediately centrifuged at 4°C. Plasma concentrations were measured radioimmunologically (12). Blood samples for renin concentration were taken after 30 min supine rest and measured directly by an improved immunoradiometric assay (13) …”
Section: Methodsmentioning
confidence: 99%
“…Plasma angiotensinogen concentration was determined using the principle of antibody trapping 22 as modified by Millar et al 23 Plasma renin activity was determined by a double-sided immunoradiometric method, using two monoclonal antibodies against human-active renin linked to biotin and 125 I (Nichols Institute, Geneva, Switzerland). Angiotensin II (Ang II rabbit-antibody kindly provided by Professor Jan Danser, Rotterdam, Holland) 24 and aldosterone (DSL-8600 active aldosterone TM Coated-Tube Ria Kit, Diagnostics Systems Laboratories Inc., Webster, Texas, USA) were measured in plasma by radioimmunoassay. For plasma angiotensinogen, women taking anticontraceptive medication (22 subjects, 18 controls) and two outliers deviating from the mean by three (a control) and five (an EH-offspring) standard deviations were excluded from calculation.…”
Section: Protocolmentioning
confidence: 99%
“…Blood was collected in EDTA aprotinin tubes and plasma was extracted on Sep-pak C18 prior to analysis. Active plasma renin concentrations were determined using the principle of antibody trapping 22 as modified by Millar et al 23 Plasma angiotensin II concentrations were measured according to the method of Kappelgaard et al 24 with the modification that Sep-Pac C 18 (Millipore Waters) was used for plasma extraction. Plasma aldosterone concentrations were measured using a commercial kit (DSL-8600, Diagnostic Systems Laboratories Inc., Webster, TE, USA).…”
Section: Assaysmentioning
confidence: 99%