Measurement of air–water CO2 transfer at four coastal sites using a chamber method

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
16
0

Year Published

2010
2010
2020
2020

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 21 publications
(16 citation statements)
references
References 23 publications
0
16
0
Order By: Relevance
“…For the data gap between two water side measurements, the time series of dissolved CO 2 was approximated through linear interpolation from the preincubation and postincubation concentration as described in Tokoro et al . []. The 90% response time for aqueous CO 2 measurement is less than 90 s. The flux of CO 2 as a function of time was calculated as: F(t)=dCdtVS, where dCdt is the change of CO 2 concentration inside of the chamber (in units of mol/L), and the concentration of CO 2 was obtained from the measured partial pressure.…”
Section: Methodsmentioning
confidence: 99%
“…For the data gap between two water side measurements, the time series of dissolved CO 2 was approximated through linear interpolation from the preincubation and postincubation concentration as described in Tokoro et al . []. The 90% response time for aqueous CO 2 measurement is less than 90 s. The flux of CO 2 as a function of time was calculated as: F(t)=dCdtVS, where dCdt is the change of CO 2 concentration inside of the chamber (in units of mol/L), and the concentration of CO 2 was obtained from the measured partial pressure.…”
Section: Methodsmentioning
confidence: 99%
“…The fCO 2 analyser mentioned above was connected to the chamber by a Teflon tube for measurement of fCO 2 inside the chamber. Details of this method are described elsewhere (Tokoro et al ., , ). The validity of the method has been quantitatively confirmed by a comparison of turbulence near the water surface inside and outside of the floating chamber (Tokoro et al ., ; Vachon et al ., ).…”
Section: Methodsmentioning
confidence: 99%
“…The floating chamber (FC) technique has been used in previous studies (Borges et al, 2004a;Tokoro et al, 2007;Vachon et al, 2010) to provide estimates of gas transfer velocity at short time scales (~20 minutes). The FC has been criticized by several researchers because the chamber covers the water surface and eliminates wind stress (Raymond and Cole, 2001) and because interference from the chamber itself results in artificially higher estimates of transfer velocity (Borges et al, 2004b).…”
Section: Introductionmentioning
confidence: 99%
“…The FC has been criticized by several researchers because the chamber covers the water surface and eliminates wind stress (Raymond and Cole, 2001) and because interference from the chamber itself results in artificially higher estimates of transfer velocity (Borges et al, 2004b). Tokoro et al (2007) pointed out that comparison of turbulent conditions inside and outside of the chamber's perimeter is needed to determine gas exchange velocities quantitatively using the FC technique. Tokoro et al (2008) measured turbulent kinetic energy (TKE) inside and outside a chamber's perimeter using a single acoustic Doppler velocimeter (ADV).…”
Section: Introductionmentioning
confidence: 99%