2014
DOI: 10.1364/boe.5.004374
|View full text |Cite
|
Sign up to set email alerts
|

Measurement of a multi-layered tear film phantom using optical coherence tomography and statistical decision theory

Abstract: To extend our understanding of tear film dynamics for the management of dry eye disease, we propose a method to optically sense the tear film and estimate simultaneously the thicknesses of the lipid and aqueous layers. The proposed method, SDT-OCT, combines ultra-high axial resolution optical coherence tomography (OCT) and a robust estimator based on statistical decision theory (SDT) to achieve thickness measurements at the nanometer scale. Unlike conventional Fourier-domain OCT where peak detection of layers … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0
1

Year Published

2015
2015
2021
2021

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 24 publications
(12 citation statements)
references
References 22 publications
0
11
0
1
Order By: Relevance
“…Using a maximum likelihood (ML) approach, Huang et al [40] proposed an algorithm for super-resolved OCT measurement and applied it to an in vitro tear film phantom measurement. To the best of our knowledge, our approach based on measurements of the OCT reflectance to obtain super-resolved thickness maps is new in the OCT field.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Using a maximum likelihood (ML) approach, Huang et al [40] proposed an algorithm for super-resolved OCT measurement and applied it to an in vitro tear film phantom measurement. To the best of our knowledge, our approach based on measurements of the OCT reflectance to obtain super-resolved thickness maps is new in the OCT field.…”
Section: Discussionmentioning
confidence: 99%
“…Low-pass filtering is physically applied before discretization, because of the finite spectral resolution of the detection [40]. This low-pass filtering leads to a finite depth range [1].…”
Section: A2 Detected Spectral Arraymentioning
confidence: 99%
“…Finally, computationally intensive emerging methods for thickness estimation using OCT raw spectra may be investigated in the future as a mean to further push accuracy and precision in the estimation of thickness if such capability may be leveraged by manufacturers. 19 The method proposed in this paper yields a precision of 0.2 μm and an accuracy of 0.1 μm based on the microscope cover slip validation experiment, in addition to being automatic and fast (full thickness map is generated in less than one minute after the alignment of the lens to the GD-OCM microscope is performed). 33 Results from the current study also establish a benchmark against which other methods may be compared.…”
Section: Discussionmentioning
confidence: 99%
“…The system layout was detailed in our previous study. 16 In summary, the key components of the system consist of a commercial broadband light source, a custom bandpass filter, and a custom broadband astigmatism-corrected Czerny-Turner spectrometer. 21 The supercontinuum laser (WhiteLase Micro, Fianium) is filtered to operate in the spectral window of 600 to 1000 nm.…”
Section: Customized Optical Coherence Tomography Instrumentationmentioning
confidence: 99%
“…To overcome this limitation, we have recently reported a maximum-likelihood (ML) estimator for the tear film thickness measurement. [16][17][18] The purpose of this study is to benchmark the noise properties of different broadband sources, including supercontinuum, SLD, and swept sources, and to investigate the performance of different sources for a thickness estimation task, with both FFT and ML estimators. For such a purpose, the rest of the paper is organized as follows.…”
Section: Introductionmentioning
confidence: 99%