1995
DOI: 10.1093/clinchem/41.10.1439
|View full text |Cite
|
Sign up to set email alerts
|

Measurement of a more stable region of osteocalcin in serum by ELISA with two monoclonal antibodies

Abstract: Intact human osteocalcin purified from femoral bones as well as tryptic fragments of the intact molecule [amino acids (aa) 1-19, 20-43, and 45-49] were used to raise and screen monoclonal antibodies (MAbs). A two-site ELISA for measurement of human osteocalcin in serum was developed with use of these MAbs. A MAb recognizing midregion human osteocalcin (aa20-43) was used as capture antibody, and an NH2 terminus (aa7-19)-specific peroxidase-conjugated MAb was used for detection. Human osteocalcin obtained from b… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
54
0
1

Year Published

1999
1999
2020
2020

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 161 publications
(56 citation statements)
references
References 19 publications
1
54
0
1
Order By: Relevance
“…Antibodies that recognize both the intact (1-49) and the amino-terminal fragment (N-Mid-osteocalcin; 1-43) were used. (19) For both osteocalcin and CTx, the total CV was Ͻ6%. Alkaline phosphatase (ALP) and bone-specific ALP (bone-ALP) were measured spectrophotometrically using an automated instrument (Hi-…”
Section: Clinic Visits and Measurementsmentioning
confidence: 98%
“…Antibodies that recognize both the intact (1-49) and the amino-terminal fragment (N-Mid-osteocalcin; 1-43) were used. (19) For both osteocalcin and CTx, the total CV was Ͻ6%. Alkaline phosphatase (ALP) and bone-specific ALP (bone-ALP) were measured spectrophotometrically using an automated instrument (Hi-…”
Section: Clinic Visits and Measurementsmentioning
confidence: 98%
“…The inter-and intra-assay CV were 10% and 8%, respectively. Plasma osteocalcin was measured by ELISA using an automated instrument (Elecsys, 2010 immunoassay analyzer, Roche Diagnostics, Basel, Switzerland) with antibodies that recognise both intact-(1-49) and N-Mid-osteocalcins (1-43) [23]. The total CV was less than 5%.…”
Section: Measurements and Biochemistrymentioning
confidence: 99%
“…27,28 Serum osteoprotegerin (OPG) and osteocalcin (OCN) concentrations were quantified with an enzyme-linked immunosorbent assay. ** 29,30 Samples were analyzed by the Clinical Analysis Department of the San Cecilio University Hospital, Granada, Spain, which provided the reference values.…”
Section: Biochemical Variablesmentioning
confidence: 99%