1983
DOI: 10.1364/ao.22.003406
|View full text |Cite
|
Sign up to set email alerts
|

Measurement of a Gaussian laser beam diameter through the direct inversion of knife-edge data

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
168
0
4

Year Published

1999
1999
2018
2018

Publication Types

Select...
8
1
1

Relationship

0
10

Authors

Journals

citations
Cited by 324 publications
(172 citation statements)
references
References 8 publications
0
168
0
4
Order By: Relevance
“…Laser pulses of wavelength of 800 nm, duration of 60 fs, and energy in the range of 1.3-4.6 lJ (measured carefully with a power meter working in a single pulse mode) were focused at the sample surface with a lens. Determining the beam radius with the knife-edge method 19,20 showed that the spatial profile of the beam used in our experiment is fitted well with a sum of two Gaussian profiles. 21 The radii of both Gaussian components were equal to: r 1 ¼ (33.8 6 0.5)lm, r 2 ¼ (217 6 21)lm, with a dominant contribution of (98.6 6 0.4)% of the first one.…”
Section: Methodsmentioning
confidence: 68%
“…Laser pulses of wavelength of 800 nm, duration of 60 fs, and energy in the range of 1.3-4.6 lJ (measured carefully with a power meter working in a single pulse mode) were focused at the sample surface with a lens. Determining the beam radius with the knife-edge method 19,20 showed that the spatial profile of the beam used in our experiment is fitted well with a sum of two Gaussian profiles. 21 The radii of both Gaussian components were equal to: r 1 ¼ (33.8 6 0.5)lm, r 2 ¼ (217 6 21)lm, with a dominant contribution of (98.6 6 0.4)% of the first one.…”
Section: Methodsmentioning
confidence: 68%
“…The target setup is maintained under vacuum with a chamber pressure of 5 × 10 −6 mbar. The variation of the laser spot size as a function of target position was measured separately using a scanning knife edge technique 15 for accurate estimation of the focused laser spot from which the on-target power density was found.…”
Section: Fig 2 (Color Online)mentioning
confidence: 99%
“…A picosecond pulsed laser system (PL2143A, 26ps) and an optical parametric generator (PG 401/SH), both from EKSPLA, were used as light sources. These sources were focused with a focal length of 500 mm, where in each case the beam waist was measured by means of the knife's edge method (Khosrofian & Garetz, 1983). The Rayleigh length was calculated to be around 1 cm for all the wavelengths considered, much larger than the thickness of the samples.…”
Section: Synthesis Of Isotropic Metallic Nanocomposites and Optical Mmentioning
confidence: 99%