2003
DOI: 10.1109/tdei.2003.1255776
|View full text |Cite
|
Sign up to set email alerts
|

Measurement equipment for investigation of the influence of viscosity of dielectric working fluids on spark erosion

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
1
0

Year Published

2004
2004
2024
2024

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 11 publications
(5 citation statements)
references
References 1 publication
0
1
0
Order By: Relevance
“…With the help of the video recordings only the expansion of the gas bubble can be determined with sufficient accuracy. The propagation of the plasma channel is much faster and also often results in a constancy of the system, which has already been detected by HSFC recordings [3].…”
Section: Collapse Of the Gas Bubblementioning
confidence: 64%
See 1 more Smart Citation
“…With the help of the video recordings only the expansion of the gas bubble can be determined with sufficient accuracy. The propagation of the plasma channel is much faster and also often results in a constancy of the system, which has already been detected by HSFC recordings [3].…”
Section: Collapse Of the Gas Bubblementioning
confidence: 64%
“…The only question is which can be determined according to the final diameter of the plasma channel, the reference to the crater (single pulse) [1], [2]. More accurate simulations take into account expansion of the plasma channel, the enthalpy and heat capacity of the electrode materials and consideration of the working medium and the pressure dependence (gas bubble expansion) of the physical parameters [3], [4]. Under given experimental conditions, the individual discharges can also be measured under actual conditions of contamination [5].…”
Section: Introductionmentioning
confidence: 99%
“…This analysis can be carried out with an exactness of 500 nm. For making a comparison between the CLSM-analysis and the HSFC-images, all the observations were done in the same measuring cell [1,3].…”
Section: Experimental Methodsmentioning
confidence: 99%
“…Based on the description of EDM currents presented in Refs [28,29], the capacitive discharge consists of the following phases:…”
Section: Origin and Identification Of Edm Currentsmentioning
confidence: 99%
“…It is worth mentioning that the variation of DA throughout the test duration was not considered in this test; therefore, the discharge occurrence frequency expressed in Figure 8 is the average frequency. The chosen test intervals and limit values for each parameter were set based on the literature [19,20,[28][29][30], as well as the test bench limitations. For example, the voltage test values were initially set to (5…30) V. Then, the results showed rare occurrence of discharge for voltage levels above 20 V; this justifies not taking these values into consideration in the following results.…”
Section: Operation Conditions Effect On Discharge Activitymentioning
confidence: 99%