2013
DOI: 10.4037/nci.0b013e318274ba3e
|View full text |Cite
|
Sign up to set email alerts
|

Measurement and Rate Correction of the QT Interval

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
2
0
4

Year Published

2014
2014
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(6 citation statements)
references
References 34 publications
0
2
0
4
Order By: Relevance
“…In our study, global QTc interval (12 leads) 12,13 was determined by an automatic application of ECG device, type "Schiller Cardiovit AT-1", which uses "SCHILLER ECG Measurement and Interpretation Software for Children and Adult ECGs" (developed by SCHILLER AG, Altgasse 68, CH-6341 Baar, Switzerland, see http://www.schiller.ch). Global QTc interval represents the interval with the earliest QRS onset and the latest T end in any lead.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…In our study, global QTc interval (12 leads) 12,13 was determined by an automatic application of ECG device, type "Schiller Cardiovit AT-1", which uses "SCHILLER ECG Measurement and Interpretation Software for Children and Adult ECGs" (developed by SCHILLER AG, Altgasse 68, CH-6341 Baar, Switzerland, see http://www.schiller.ch). Global QTc interval represents the interval with the earliest QRS onset and the latest T end in any lead.…”
Section: Methodsmentioning
confidence: 99%
“…Examination of automatic measurement by the coincidence of heart frequencies in V3 lead using classical method was done. Patients with double and biphasic T waves were not included in the study, while T wave amplitude was greater than 0.2 mV 12 .…”
Section: Methodsmentioning
confidence: 99%
“…Mjerenje je vršeno kod pacijenta u mirovanju (u ležećem položaju) tokom 20 sekundi. U našoj studiji globalni QTc interval (12odvodni) (7,8), određivan je automatski primjenom EKG aparata proizvođača i tipa "Schiller Cardiovit AT-1" koji koristi "SCHILLER ECG Measurement and Interpretation Software for Children and Adult ECGs" (razvijen od SCHILLER AG, Altgasse 68, CH-6341 Baar, Switzerland, vidi http://www.schiller.ch). Globalni QTc interval predstavlja interval sa najranijim QRS početkom i najkasnijim T krajem u bilo kojem odvodu.…”
Section: Ispitanici I Metodeunclassified
“…U našoj studiji globalni QTc interval (12-odvodni) [13,14], određivan je automatski primjenom EKG aparata proizvođača i tipa "Schiller Cardiovit AT-1" koji koristi "SCHILLER ECG Measurement and Interpretation Software for Children and Adult ECGs" (razvijen od SCHIL-LER AG, Altgasse 68, CH-6341 Baar, Switzerland, vidi http://www.schiller.ch). Globalni QTc interval predstavlja interval sa najranijim QRS početkom i najkasnijim T krajem u bilo kojem odvodu.…”
Section: Metode Radaunclassified
“…Vršena je provjera automatskog mjerenja podudaranjem srčanih frekvencija u V3 odvodu klasičnom metodom. Pacijenti sa dvostrukim i bifazičnim T talasima nisu uključeni u studiju, a amplituda T talasa je bila veća od 0,2 mV [13].…”
Section: Metode Radaunclassified