Measurement and modification of free calcium transients in frog skeletal muscle fibres by a metallochromic indicator dye.

Abstract: SUMMARY1. Myoplasmic free calcium transients were monitored with the metallochromic indicator dye Antipyrylazo III (AP III) in single frog skeletal muscle fibres cut at both ends, stretched so as to minimize or eliminate contractile filament overlap and voltage clamped using a double-Vaseline-gap system ( s 6 0C).2. The dye entered the central fibre segment by diffusion from the solution applied to the two cut ends. The diffusion coefficient of AP III was about 20 times lower in the fibre than in solution. Thi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

13
205
2

Year Published

1985
1985
2007
2007

Publication Types

Select...
5
2
2

Relationship

0
9

Authors

Journals

citations
Cited by 185 publications
(220 citation statements)
references
References 23 publications
13
205
2
Order By: Relevance
“…The fibers were mounted in a double Vaseline-gap chamber (Kov~cs, Rios, and Schneider, 1983;Irving, Maylie, Sizto, and Chandler, 1987), stretched to a sarcomere length of 3.4-4.2 ttm, and studied at 14-15~ with the experimental methods used previously in this laboratory. The optical apparatus and method for the estimation of indicator-related absorbance signals are described in Irving et al (1987) and Maylie, Irving, Sizto, and Chandler (1987).…”
Section: Methodsmentioning
confidence: 99%
“…The fibers were mounted in a double Vaseline-gap chamber (Kov~cs, Rios, and Schneider, 1983;Irving, Maylie, Sizto, and Chandler, 1987), stretched to a sarcomere length of 3.4-4.2 ttm, and studied at 14-15~ with the experimental methods used previously in this laboratory. The optical apparatus and method for the estimation of indicator-related absorbance signals are described in Irving et al (1987) and Maylie, Irving, Sizto, and Chandler (1987).…”
Section: Methodsmentioning
confidence: 99%
“…Fibres were allowed to rest after enzymatic treatment for at least 20 min and only those that showed no signs of membrane damage were used. The selected fibre was gently sucked into a glass capillary and transferred into the recording chamber (Kov acs et al 1983) filled with relaxing solution (composition (mÒ): 150 potassium glutamate, 2 MgClµ, 10 Hepes, 1 EGTA).…”
Section: Methods Enzymatic Dissociation and Solutionsmentioning
confidence: 99%
“…1, left column) as described by Kov acs et al (1983) using the correction for intrinsic fibre absorbance at 850 nm following the procedure in Melzer et al (1986). Fura_2 fluorescence was used to calculate the resting [Ca¥]é.…”
Section: Calculation [Ca¥]é and Rrelmentioning
confidence: 99%
“…The fibers were mounted in a double Vaseline-gap chamber, similar to that used by Kovacs et al (1983). To facilitate indicator entry, the surface membranes in the end pools were made permeable by a 2-rain exposure to 0.01% saponin (Endo and Iino, 1980).…”
Section: Methodsmentioning
confidence: 99%