2015
DOI: 10.1021/ie502557g
|View full text |Cite
|
Sign up to set email alerts
|

Measurement and Modeling of Phase Equilibria in Systems of Acetonitrile,n-Alkanes, and β-Myrcene

Abstract: This work presents a modeling approach using the Perturbed Chain-Statistical Associating Fluid Theory (PC-SAFT) for new liquid−liquid equilibria (LLE) data of ternary systems containing β-myrcene, acetonitrile, and n-alkanes, as well as binary mixtures thereof. The modeling approach is based on parameter estimations from binary systems and allows a general prediction of acetonitrile/n-alkane systems' LLE and their ternary mixtures' LLE with β-myrcene. The binary mixtures' vapor− liquid equilibria (VLE) of β-my… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
37
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 18 publications
(37 citation statements)
references
References 20 publications
(11 reference statements)
0
37
0
Order By: Relevance
“…The GC system Agilent Technology 7890A instrument was equipped with an HP 5 column (5% phenyl methyl siloxan; 30 m, 0.32 mm, 0.25 μm) and a flame ionization detector as in our previous work. 8 Vapor−Liquid Equilibrium (VLE) Measurements. VLE measurements of binary systems were performed using a glass apparatus (Normag, Ilbisheim, Germany) equipped with electrical heating, an oil-filled double-jacketed equilibrium chamber, and a water-cooled condenser for the vapor phase.…”
Section: ■ Methodsmentioning
confidence: 99%
See 4 more Smart Citations
“…The GC system Agilent Technology 7890A instrument was equipped with an HP 5 column (5% phenyl methyl siloxan; 30 m, 0.32 mm, 0.25 μm) and a flame ionization detector as in our previous work. 8 Vapor−Liquid Equilibrium (VLE) Measurements. VLE measurements of binary systems were performed using a glass apparatus (Normag, Ilbisheim, Germany) equipped with electrical heating, an oil-filled double-jacketed equilibrium chamber, and a water-cooled condenser for the vapor phase.…”
Section: ■ Methodsmentioning
confidence: 99%
“…All substances except morpholine were already modeled with PC-SAFT. 8 Thus, pure-component parameters had to be estimated only for morpholine. This was done by fitting the three PC-SAFT parameters, σ i , m i , and u i /k B , as well as the permanent dipole moment of morpholine to vapor pressure 19,21−27 and liquid density 20−24 data.…”
Section: ■ Methodsmentioning
confidence: 99%
See 3 more Smart Citations