1988
DOI: 10.1016/0375-9474(88)90242-4
|View full text |Cite
|
Sign up to set email alerts
|

Measured gyromagnetic ratios and the low-excitation spectroscopy of 197Au

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
11
0

Year Published

1988
1988
2020
2020

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 26 publications
(11 citation statements)
references
References 33 publications
0
11
0
Order By: Relevance
“…While only the overall transition intensity was adjusted to fit the data for the 548-keV E2 transition, the mixing ratios were also varied to fit the correlations for the mixed were also in agreement with those measured and are similar to those published for la4W in [13]. A partial level scheme of 197Au which incorporates several firm spin assignments determined in our related study [20,21] is shown in Fig. 5.…”
Section: Resultsmentioning
confidence: 91%
See 2 more Smart Citations
“…While only the overall transition intensity was adjusted to fit the data for the 548-keV E2 transition, the mixing ratios were also varied to fit the correlations for the mixed were also in agreement with those measured and are similar to those published for la4W in [13]. A partial level scheme of 197Au which incorporates several firm spin assignments determined in our related study [20,21] is shown in Fig. 5.…”
Section: Resultsmentioning
confidence: 91%
“…In earlier publications [5,6,8] we discussed the abrupt discontinuity in TF strength which occurs between 76Os and 7sPt ions traversing polarized Fe hosts with velocities ~ 0.02 c. In contrast with TF studies using Fe hosts, no discontinuities [20,21]. Shown at the left of each level are the relative direct population intensities (with that to the 5/2~-taken as 100) derived from the measured particle-7 correlation data of Run II.…”
Section: Transient Field Calibration and G-factors Resultsmentioning
confidence: 97%
See 1 more Smart Citation
“…The mixing ratios were determined from the measured angular correlations by procedures similar to those described in Refs. [18] and [19]. Results are summarized and compared with those of previous work [9] in Table III.…”
Section: -2mentioning
confidence: 93%
“…[23, 24,25,26,27,28,29,30,31,32,33,34,35,36,37,38,39,40,41,42,43]. One caveat on this statement is that S(θ γ ) is a very sensitive function of θ γ when the detectors are placed near the maximum slope of the angular correlation as is done for precession measurements.…”
Section: Transient-field Impacmentioning
confidence: 99%