2017 IEEE Applied Power Electronics Conference and Exposition (APEC) 2017
DOI: 10.1109/apec.2017.7930857
|View full text |Cite
|
Sign up to set email alerts
|

Maximum power point tracking control of a high power dc-dc converter for PV integration in MVDC distribution grids

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
6
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 21 publications
(6 citation statements)
references
References 14 publications
0
6
0
Order By: Relevance
“…The work reported in Hu et al 61 shows a modified DAB converter interfacing a PV array, which proposes six transistors instead of the four used in the traditional structure. In addition, the converter includes a multiport transformer, which is intended to raise the 1.5 kV delivered by the PV array up to the 10 kV required by a microgrid.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The work reported in Hu et al 61 shows a modified DAB converter interfacing a PV array, which proposes six transistors instead of the four used in the traditional structure. In addition, the converter includes a multiport transformer, which is intended to raise the 1.5 kV delivered by the PV array up to the 10 kV required by a microgrid.…”
Section: Resultsmentioning
confidence: 99%
“…The first approach adopted in literature to control DAB converters are PI and PID controllers, such as the works reported in previous works 35‐37,61‐65 . Those solutions provide a complete description of the model and design process, but the solutions are not validated considering perturbations.…”
Section: Discussionmentioning
confidence: 99%
“…Those solutions give a comprehensive explanation of the system model and schematic design, but they are not verified in the presence of perturbations. Furthermore, in [89][90][91], PI and PID controllers must take into account the linearization of the plant model, affecting the controller robustness, and do not often ensure the performance of a system. Another criterion is met in [92], which design nonlinear control techniques.…”
Section: Discussionmentioning
confidence: 99%
“…IsBDC are usually used when the voltage difference between the DC bus and the battery is large [71]. The presence of high frequency transformers and variety of components in various IsBDC topologies [60,61,[72][73][74][75][76][77][78] cause large converter size with applications in static energy storage. NIBDC are simple in structure, lightweight and simple to regulate.…”
Section: Need For Bdc and Essmentioning
confidence: 99%