Maximum and Average Urine Flow Rates in Normal Male and Female Populations—the Liverposl Nomograms

Abstract: The study of voiding in men and women has been handicapped by the lack of a normal reference range covering urinary flow rates over a wide range of voided volumes. Normal volunteers (331 males and 249 females) were studied. Each voided once into a calibrated Dantec Urodyn 1000 mictiograph. On a second occasion 282 men and 46 women voided. The maximum and average urine flow rates of the first voids in both sexes were compared with the respective voided volumes. Nomogram charts, in centile form, for both the max… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

11
233
2
9

Year Published

1994
1994
2016
2016

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 324 publications
(257 citation statements)
references
References 18 publications
11
233
2
9
Order By: Relevance
“…Consistency of repeated measurements has been reported in various studies, including the one by Prof. Haylen et al 14 and us too. 15 Similarly, as nicely depicted by Prof Haylen et al 14 there is remarkable consistency of centile ranking of repeated voids, therefore, negating its importance in construction and validation purpose for nomograms.…”
mentioning
confidence: 82%
“…Consistency of repeated measurements has been reported in various studies, including the one by Prof. Haylen et al 14 and us too. 15 Similarly, as nicely depicted by Prof Haylen et al 14 there is remarkable consistency of centile ranking of repeated voids, therefore, negating its importance in construction and validation purpose for nomograms.…”
mentioning
confidence: 82%
“…59 To correct for this relationship, some individuals have developed nomograms, but there has not been one that has become universally accepted. [60][61][62][63][64][65][66][67][68] Another weakness of using the maximum flow rate to diagnose BPH is that is tends to have diurnal and day to day variability. 50,69 Most BPH trials tend to use flow rates less than 10-15 ml s À1 as entry criteria.…”
Section: Maximum Flow Ratesmentioning
confidence: 99%
“…When results of the flow studies are entered, the program plots the values on four published nomograms for flow studies -Rollema (Q max and T void ), 6 Susset 7 and Haylen. 8 Three of these are Q max nomograms and one is for voiding time. The nomograms are used to score the flow between 0 (unobstructed) and 2 (obstructed).…”
Section: Data Analysis and Decision-makingmentioning
confidence: 99%