2006
DOI: 10.1063/1.2219723
|View full text |Cite
|
Sign up to set email alerts
|

MAXIMA: A balloon-borne cosmic microwave background anisotropy experiment

Abstract: We describe the Millimeter wave Anisotropy eXperiment IMaging Array ͑MAXIMA͒, a balloon-borne experiment which measured the temperature anisotropy of the cosmic microwave background ͑CMB͒ on angular scales of 10Ј to 5°. MAXIMA mapped the CMB using 16 bolometric detectors in spectral bands centered at 150, 240, and 410 GHz, with 10Ј resolution at all frequencies.The combined receiver sensitivity to CMB anisotropy was ϳ40 K ͱ s. The bolometric detectors, which were cooled to 100 mK, were a prototype of the detec… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0

Year Published

2010
2010
2023
2023

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 17 publications
(13 citation statements)
references
References 45 publications
0
13
0
Order By: Relevance
“…These receivers (such as the Millimeter wave Anisotropy eXperiment IMaging Array (MAXIMA; Ref. 16) and Balloon Observations Of Millimetric Extragalactic Radiation and Geophysics (BOOMERanG; Ref. 17) each with 16 detectors) used neutron-transmutation-doped (NTD) bolometers.…”
Section: Opticsmentioning
confidence: 99%
“…These receivers (such as the Millimeter wave Anisotropy eXperiment IMaging Array (MAXIMA; Ref. 16) and Balloon Observations Of Millimetric Extragalactic Radiation and Geophysics (BOOMERanG; Ref. 17) each with 16 detectors) used neutron-transmutation-doped (NTD) bolometers.…”
Section: Opticsmentioning
confidence: 99%
“…Single-shot, single-stage ADRs must limit parasitic conduction to achieve long hold times, so benefit from mechanical heat switches 16 or backing coolers 12 . In contrast, lower inter-stage parasitic power in the multistage CADR allows for the use of gas-gap switches, which avoid mechanisms, or any electrical input (in the case of passive 33 switches).…”
Section: G Comparison To Single-shot Adr Systemsmentioning
confidence: 99%
“…Several other publications give additional details about the EBEX experiment. Some are from earlier stages of the program (Oxley et al 2004;Grainger et al 2008;Aubin et al 2010;Milligan et al 2010;Reichborn-Kjennerud et al 2010;Klein et al 2011;Sagiv et al 2012;Westbrook et al 2012), and others discuss some subsystems in more detail (Polsgrove 2009; Reichborn-Kjennerud 2010; Sagiv 2011; Aubin 2012;MacDermid 2014;MacDermid et al 2014;Westbrook 2014;Zilic 2014;Chapman 2015;Chapman et al 2015;Didier et al 2015;Aubin et al 2016;Didier 2016).…”
Section: Introductionmentioning
confidence: 99%