1997
DOI: 10.1021/es960671q
|View full text |Cite
|
Sign up to set email alerts
|

Matrix-Enhanced Degradation of p,p‘-DDT during Gas Chromatographic Analysis:  A Consideration

Abstract: Analysis of p,p‘-DDT in environmental samples requires monitoring the GC-derived breakdown of this insecticide, which produces p,p‘-DDD and/or p,p‘-DDE, both also primary environmental degradation products. A performance evaluation standard (PES) containing p,p‘-DDT but not p,p‘-DDD or p,p‘-DDE can be injected at regular intervals throughout an analytical sequence to monitor GC degradation. Some U.S. EPA methods limit GC breakdown of DDT in the PES to ≤20%. GC/MS analysis of large-volume natural water samples … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
27
0

Year Published

2002
2002
2017
2017

Publication Types

Select...
8
2

Relationship

0
10

Authors

Journals

citations
Cited by 68 publications
(27 citation statements)
references
References 20 publications
0
27
0
Order By: Relevance
“…This effect is more apparent at lower concentrations than higher concentrations (table 4). Other GC methods note degradation in the injection port and the need for required maintenance and quality-control samples for other compounds (Foreman, 1997;Munch, 1995). ----1 Laboratory 1 used a liquid chromatography tandem mass spectrometry analytical method.…”
Section: Methods Validationmentioning
confidence: 99%
“…This effect is more apparent at lower concentrations than higher concentrations (table 4). Other GC methods note degradation in the injection port and the need for required maintenance and quality-control samples for other compounds (Foreman, 1997;Munch, 1995). ----1 Laboratory 1 used a liquid chromatography tandem mass spectrometry analytical method.…”
Section: Methods Validationmentioning
confidence: 99%
“…With a longer extraction period (16 hours) or the use of Soxhlet extraction the apparent recovery of the DDX increases drastically to levels above 100%. This increase is attributed to analyte decomposition [30] and matrix enhancement effects [31] in the GC liner. This is reasonable as a Judging from the data obtained during this study PCBs do not seem to be a point of concern during SLE from soils.…”
Section: Dependence On Soil Typementioning
confidence: 99%
“…Before instrumental analysis, the extent for breakdown of p,p′-DDT was less than 20% through the analysis of a standard solution of p,p′-DDT. 31 ■ RESULTS AND DISCUSSION Measurement of Sampling Rate (R). The sampling rate (R) can be expressed as (Text S4 of the Supporting Information )…”
Section: Multi-section Passive Samplermentioning
confidence: 99%