2014
DOI: 10.1016/j.sab.2014.09.003
|View full text |Cite
|
Sign up to set email alerts
|

Matrix effects in laser ablation molecular isotopic spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
25
0

Year Published

2016
2016
2020
2020

Publication Types

Select...
4
1

Relationship

1
4

Authors

Journals

citations
Cited by 11 publications
(26 citation statements)
references
References 54 publications
1
25
0
Order By: Relevance
“…For the purpose of the present study, the corrected Kurucz database [28] was adequate for spectra simulation. is an appropriate choice for isotopic analysis of 13 C because the line positions from the 13 C 12 C isotopologue is red shifted from the more abundant 12 C 12 C. As the bandheads of the C 2 d 3 Π ga 3 Π u system degrade to blue, the red-shifted 13 C 12 C (1-0) bandhead appears in front of and not buried inside the decaying part of the dominant 12 C 2 bandhead. However, other rovibronic structures from the Swan band, in particular those from 0-0, 1-1 and 9-8 [21], of the dominant 11 12 C 2 isotopologue emit in close wavelength proximity to the bandhead of 13…”
Section: Computer Simulationmentioning
confidence: 99%
See 4 more Smart Citations
“…For the purpose of the present study, the corrected Kurucz database [28] was adequate for spectra simulation. is an appropriate choice for isotopic analysis of 13 C because the line positions from the 13 C 12 C isotopologue is red shifted from the more abundant 12 C 12 C. As the bandheads of the C 2 d 3 Π ga 3 Π u system degrade to blue, the red-shifted 13 C 12 C (1-0) bandhead appears in front of and not buried inside the decaying part of the dominant 12 C 2 bandhead. However, other rovibronic structures from the Swan band, in particular those from 0-0, 1-1 and 9-8 [21], of the dominant 11 12 C 2 isotopologue emit in close wavelength proximity to the bandhead of 13…”
Section: Computer Simulationmentioning
confidence: 99%
“…The PLS algorithm used in this study was a PLS1 type and is similar to the one previously described [2,10,11]. A library of standard spectra from eleven (unless otherwise specified) standards with 13 C abundances evenly distributed between 0% and 2% was complied. For each standard, there were ten simulated spectra, and each spectrum comprised accumulated signals from 100 laser shots (unless otherwise specified).…”
Section: Computer Simulationmentioning
confidence: 99%
See 3 more Smart Citations