Matrix effect marker for multianalyte analysis by LC–MS/MS in biological samples

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
14
0

Year Published

2014
2014
2020
2020

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 27 publications
(14 citation statements)
references
References 19 publications
(21 reference statements)
0
14
0
Order By: Relevance
“…Obviously and because of the limitations (sample volume) and ethical constrains in neonates, such studies should first be done using samples for adult patients. Matrix effects (ion suppression/enhancement) should hereby be considered, since this is a well-observed phenomenon in analyses of biological matrices by high-performance liquid chromatography-mass spectrometry (LC-MS) [13]. This should be followed by subsequent hypothesis testing, validation, or confirmation in neonatal matrix.…”
Section: Resultsmentioning
confidence: 99%
“…Obviously and because of the limitations (sample volume) and ethical constrains in neonates, such studies should first be done using samples for adult patients. Matrix effects (ion suppression/enhancement) should hereby be considered, since this is a well-observed phenomenon in analyses of biological matrices by high-performance liquid chromatography-mass spectrometry (LC-MS) [13]. This should be followed by subsequent hypothesis testing, validation, or confirmation in neonatal matrix.…”
Section: Resultsmentioning
confidence: 99%
“…However, the proportion of urine specimens containing a large number of leukocytes was much higher among the specimens correctly identified by Vitek MS, suggesting that a high leukocyte count does not interfere with bacterial protein peaks. High concentrates of many endogenous substances such as α-defensins in urine, which can suppress or enhance the ionization of certain protein spectra of microorganisms, might result in incorrect or no identification [ 13 , 14 ].…”
Section: Discussionmentioning
confidence: 99%
“…Matrix effects are common in urine analyses which are already observed as interferences in the calibration straight lines (Tudela et al, 2012;Deventer et al, 2014). Human urine samples diluted in water are generally used for the preparation of these calibration straight lines (Olsson et al, 2004;Davis et al, 2013;Roca et al, 2014aRoca et al, , 2014b.…”
Section: Matrix Effectsmentioning
confidence: 99%