2008
DOI: 10.1021/ac801200w
|View full text |Cite
|
Sign up to set email alerts
|

Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometric Analysis of Cellular Glycerophospholipids Enabled by Multiplexed Solvent Dependent Analyte−Matrix Interactions

Abstract: A matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS) based approach was developed for the rapid analyses of cellular glycerophospholipids. Through multiplexed solvent-enabled optimization of analyte-matrix interactions during the crystallization process, over a 30-fold increase in S/N was achieved using 9-aminoacridine as matrix. The linearity of response (r 2 =0.99) and dynamic range of this method (over 2 orders of magnitude) were excellent. Moreover, through multiple… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

8
147
0

Year Published

2010
2010
2020
2020

Publication Types

Select...
6
4

Relationship

1
9

Authors

Journals

citations
Cited by 196 publications
(156 citation statements)
references
References 58 publications
8
147
0
Order By: Relevance
“…A mixture of 5 l of acyl CoA extract and 5 l of 9-aminoacridine solution [10 mg of 9-AA/ml in acetone/methanol (98:2, v/v)] was spotted on a MALDI plate and analyzed using a MALDI-TOF mass spectrometer ( 34 ). Quantitative analyses of acyl CoA species by MALDI-TOF-MS with 9-aminoacridine as matrix were similarly assessed as previously described ( 35,36 ) tions we use a timestep of ⌬ t ‫ف‬ 0.05-0.15. Whenever practical, a larger value of ⌬ t is used to reduce the simulation computation time.…”
Section: Acyl Coa Extraction and Analysismentioning
confidence: 99%
“…A mixture of 5 l of acyl CoA extract and 5 l of 9-aminoacridine solution [10 mg of 9-AA/ml in acetone/methanol (98:2, v/v)] was spotted on a MALDI plate and analyzed using a MALDI-TOF mass spectrometer ( 34 ). Quantitative analyses of acyl CoA species by MALDI-TOF-MS with 9-aminoacridine as matrix were similarly assessed as previously described ( 35,36 ) tions we use a timestep of ⌬ t ‫ف‬ 0.05-0.15. Whenever practical, a larger value of ⌬ t is used to reduce the simulation computation time.…”
Section: Acyl Coa Extraction and Analysismentioning
confidence: 99%
“…Far more information was obtained with lithium adducts, where products of the neutral loss of one or the other fatty acid were detected. Lithium and the other Group 1 metals have been used in the literature for structural investigations [10][11][12][13][14], although their utility in obtaining double bond information from lipids typically requires multiple stages of MS/MS and is based on neutral loss rather than direct detection of product ions [14,15].…”
Section: Introductionmentioning
confidence: 99%
“…However, PEs were easily detected from crude lipid extracts if para-nitroaniline (PNA) or 9-aminoacridine (9-AA) was used as a matrix. 3,9 In addition, inorganic matrices were also employed for this purpose. For example, colloidal graphite and gold nanoparticle matrices were shown to selectively enhance ion signals of cerebrosides (Cers), a group of glycosphingolipids, from brain tissues and lipid extracts.…”
Section: Introductionmentioning
confidence: 99%