2014
DOI: 10.1016/j.renene.2013.11.027
|View full text |Cite
|
Sign up to set email alerts
|

Mathematical modelling of counter flow v-grove solar air collector

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
30
0

Year Published

2015
2015
2021
2021

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 69 publications
(31 citation statements)
references
References 11 publications
1
30
0
Order By: Relevance
“…The model was able to correctly predict the mean temperature of any component of the air collector, the instantaneous air temperature at any section of the collector, the output air temperature, and efficiency. The simulation results were verified by experimental results available in the literature [47] and it was observed that the model had the ability to predict the performance of the air collector accurately as proven by the comparison of experimental result and simulation.…”
Section: Dpsahs With Extended Surfacementioning
confidence: 54%
See 1 more Smart Citation
“…The model was able to correctly predict the mean temperature of any component of the air collector, the instantaneous air temperature at any section of the collector, the output air temperature, and efficiency. The simulation results were verified by experimental results available in the literature [47] and it was observed that the model had the ability to predict the performance of the air collector accurately as proven by the comparison of experimental result and simulation.…”
Section: Dpsahs With Extended Surfacementioning
confidence: 54%
“…The efficiency of the collector was found to be a strong function of MFR. Performance of the flat, finned and V-corrugated absorber plate type of SAHs in both single pass and double pass mode were investigated both experimentally and theoretically by Karim and Hawladar [47]. It was reported that the V-corrugated absorber showed the highest thermal efficiency as compared to others for the same range of design and operating conditions.…”
Section: Dpsahs With Extended Surfacementioning
confidence: 99%
“…Applications of recycling operations were investigated experimentally and numerically and it was shown that the thermal performance enhancement was accomplished by increasing the heat-transfer coefficients in the wire mesh packed [13], v-grove [14] and baffled [15] solar air heaters. The influence of the wavelike flow channel of solar air collector was investigated in enhancing the thermal performance for cross-corrugated [16] and v-corrugated plates [17] solar air heaters.…”
Section: Introductionmentioning
confidence: 99%
“…This thermal energy is then conducted to the inner surface of the absorber tube and transferred to the heat transfer fluid by forced convection. This is considered a coupled heat transfer problem with complex geometrical conditions [1].…”
Section: Introductionmentioning
confidence: 99%