2020
DOI: 10.23939/mmc2020.01.169
|View full text |Cite
|
Sign up to set email alerts
|

Mathematical modeling of an air split-conditioner heat pump operation for investigation its exergetic efficiency

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
14
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
4
2

Relationship

1
5

Authors

Journals

citations
Cited by 11 publications
(14 citation statements)
references
References 4 publications
0
14
0
Order By: Relevance
“…Investigations of the results bringing the operation of heat pumps of air split-conditioners to the same internal temperature conditions and exergetic OIR are carried out on one-stage steam-compressor freon heat pumps of air split-conditioners (without effective cooling of the compressor ), which applies to air split-conditioners, the scheme is shown in Fig. 1a, and described in article [18]. The operation of the heat pump and the calculation of energy efficiency based on the construction of its thermodynamic process of operation on (p, i)-diagram (Fig.…”
Section: Methods Materials and Results Of Researchesmentioning
confidence: 99%
See 4 more Smart Citations
“…Investigations of the results bringing the operation of heat pumps of air split-conditioners to the same internal temperature conditions and exergetic OIR are carried out on one-stage steam-compressor freon heat pumps of air split-conditioners (without effective cooling of the compressor ), which applies to air split-conditioners, the scheme is shown in Fig. 1a, and described in article [18]. The operation of the heat pump and the calculation of energy efficiency based on the construction of its thermodynamic process of operation on (p, i)-diagram (Fig.…”
Section: Methods Materials and Results Of Researchesmentioning
confidence: 99%
“…Successful application of the exergetic method of analysis for different technical systems, in particular of refrigerating machines of air split-conditioners, have been grounded in the works of R. K. Clausius, John W. Gibbs, G. Gouy, A. Stodola, J. Shargut, R. Petela and V. M. Brodyansky for their technical and economic optimization and our works [8][9][10][11][12][13][14][15][16][17][18]. We have adapted this method to the analysis of heat pumps of air split-conditioners [18] and used in this article.…”
Section: Analysis Of Reference Data and Problem Solvingmentioning
confidence: 99%
See 3 more Smart Citations