2013
DOI: 10.1016/j.egypro.2013.06.744
|View full text |Cite
|
Sign up to set email alerts
|

Mathematical Modeling of an Absorption Chiller System Energized by a Hybrid Thermal System: Model Validation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 11 publications
(8 citation statements)
references
References 5 publications
0
7
0
Order By: Relevance
“…In response to the need for alternative energy sources, solar cooling technologies have become an important factor especially in hot countries due to the huge amount of solar radiation and the need for cooling. Solar cooling systems are environmentally friendly compared to conventional cooling systems and an important technology to reduce gas emissions [3]. Pazheri et al [4] estimated that a 20 MW solar plant, which would need an area of 1.25 km 2 , can generate 200 to 300 GWh/year and could save 500,000 barrels of oil per year.…”
Section: Introductionmentioning
confidence: 99%
“…In response to the need for alternative energy sources, solar cooling technologies have become an important factor especially in hot countries due to the huge amount of solar radiation and the need for cooling. Solar cooling systems are environmentally friendly compared to conventional cooling systems and an important technology to reduce gas emissions [3]. Pazheri et al [4] estimated that a 20 MW solar plant, which would need an area of 1.25 km 2 , can generate 200 to 300 GWh/year and could save 500,000 barrels of oil per year.…”
Section: Introductionmentioning
confidence: 99%
“…The relative annual benefit (RNAB) was defined as the annual profit from the use of solar system instead of the reference system which included heat pump grid electricity dependent to provide cooling and heating for the space and gas fired water heater to provide domestic hot water. The finding in this study reported that the optimum value for a stand-alone system for the CCHP were 9 CPVTs, 5 PVs, 1.97 m 3 water storage tank and 33.99 kWh battery while exergy efficiency and RNAB were 9.1% and 6279$/year respectively. The work concluded a good correlation between the simulation and experimental results that were reported from the CPVT manufacturer.…”
Section: U N C O R R E C T E D P R O O Fmentioning
confidence: 67%
“…Simple payback period (SPP) is an economic indicator that calculate the time required to pay the different between the capital cost of the proposed solar system and the reference system from the operation cost saving. The expression of SPP is written as: (3) is the difference between the capital cost of the proposed and the reference system and represents the difference between the operation cost for the reference and proposed solar systems.…”
Section: Economic Viabilitymentioning
confidence: 99%
See 1 more Smart Citation
“…The water absorption chiller consists of three parts, a high temperature generator, a refrigeration system and an evaporator [31,32]. Each component is modeled as a black-box using input-output data.…”
Section: Absorption Machine Modelmentioning
confidence: 99%