2016
DOI: 10.1016/j.ijepes.2016.04.050
|View full text |Cite
|
Sign up to set email alerts
|

Mathematical modeling and analysis of brushless doubly fed reluctance generator under unbalanced grid voltage condition

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
16
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 13 publications
(17 citation statements)
references
References 24 publications
0
16
0
Order By: Relevance
“…(The 8-pole winding is the power winding, which is wounded in the inner side of the stator, while the 4-pole winding is the control winding, which is wounded in the outer side of it). [6,17,34,48,50,54,56,57,72,[81][82][83][84][85][86][87]. In [56], the equivalent electric circuit for both the case of considering and ignoring the rotor current is presented.…”
Section: Statormentioning
confidence: 99%
See 2 more Smart Citations
“…(The 8-pole winding is the power winding, which is wounded in the inner side of the stator, while the 4-pole winding is the control winding, which is wounded in the outer side of it). [6,17,34,48,50,54,56,57,72,[81][82][83][84][85][86][87]. In [56], the equivalent electric circuit for both the case of considering and ignoring the rotor current is presented.…”
Section: Statormentioning
confidence: 99%
“…The operation of BDFRM under different conditions, such as the capability of generating reactive power for voltage drop considerations [79], open-circuit [82], and unbalanced grid voltage [83], is investigated. All grid-tied wind turbine generators must be compatible with locational system codes, as well as the reactive power considerations, and thus, need to be evaluated under grid-tied performance in the understudy zones.…”
Section: Operation In Different Conditionsmentioning
confidence: 99%
See 1 more Smart Citation
“…Under unbalanced conditions, negative-sequence components are present in the grid voltage, causing problems for wind generators such as unbalanced primary currents, current harmonics at the secondary side, unequal heating, or hot spots in the windings [30] which degrade the insulation and reduce the life expectancy of the windings, as well as producing power pulsations [31,32]. Unbalanced currents also create a pulsating torque, which may cause extra mechanical stress on the drive train and gearbox [33][34][35][36] and increase acoustic noise, too. Therefore, studying wind generators under unbalanced grid voltage conditions and designing a convenient control strategy are very important.…”
Section: Introductionmentioning
confidence: 99%
“…A new model for the BDFRG unbalanced operation was put forward in [34] using positive and negative sequence equations. The same authors used the model presented in [34] to develop a Predictive DPC (PDPC) method for the BDFRG under unbalanced grid conditions in [30].…”
Section: Introductionmentioning
confidence: 99%