2022
DOI: 10.1109/tec.2022.3169394
|View full text |Cite
|
Sign up to set email alerts
|

Matching Analysis of LVRT Grid Code and Injection Current Dependent Voltage Response of WTC Connected to High Impedance AC Grid

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(5 citation statements)
references
References 4 publications
0
4
0
Order By: Relevance
“…Then, considering that reactive current injection takes priority, and the remaining capacity is utilized for active current, the relationships can be Based on (5), there exists an inequality constraint of residual grid voltage, current references, and grid impedance, which is the precondition of the existence of PLL's equilibrium point [31] as represented by ( 16): R eq I q + X eq I d = U eq sin δ (16) where U eq is the equivalent grid impedance, namely the amplitude of U eq . Since −1 ≤ sinδ ≤ 1, (17) can be further derived into [34]:…”
Section: Feasible Current Region Of Gscmentioning
confidence: 99%
“…Then, considering that reactive current injection takes priority, and the remaining capacity is utilized for active current, the relationships can be Based on (5), there exists an inequality constraint of residual grid voltage, current references, and grid impedance, which is the precondition of the existence of PLL's equilibrium point [31] as represented by ( 16): R eq I q + X eq I d = U eq sin δ (16) where U eq is the equivalent grid impedance, namely the amplitude of U eq . Since −1 ≤ sinδ ≤ 1, (17) can be further derived into [34]:…”
Section: Feasible Current Region Of Gscmentioning
confidence: 99%
“…From (10) it can be seen that the memory unit c tÀ1 can obtain the s t through the screening of the forgetting gate, input gate and output gate as (11).…”
Section: Lstm Neural Networkmentioning
confidence: 99%
“…The voltage and frequency fluctuations caused by the high voltage ride‐though (HVRT) and low voltage ride‐though (LVRT) due to grid faults become more frequent and hazardous. Both simulation studies using commercial software and hardware‐in‐the‐loop platforms have demonstrated such adverse effects on the power system 10–12 …”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Hence, these factors necessitate consideration when evaluating the grid-connected capacity of wind power [24]. Particularly, when integrating a large-scale wind power system into the delivery side, fault overvoltage characteristics emerge from the interaction between the transient properties of the DC system and the LVRT characteristics of the wind farm [25].…”
Section: Introductionmentioning
confidence: 99%