2021
DOI: 10.1016/j.ajo.2020.12.032
|View full text |Cite
|
Sign up to set email alerts
|

Matched Cohort Study of Cataract Surgery With and Without Trabecular Microbypass Stent Implantation in Primary Angle-Closure Glaucoma

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 14 publications
(10 citation statements)
references
References 55 publications
0
9
0
Order By: Relevance
“…Another explanation could be the differences in surgical techniques. As detailed in our previous studies of the iStent inject, [ 15 18 ] the stents were implanted into the trabecular meshwork, adjacent to the collector channels (identified and marked preoperatively, as described in “ Methods ”), to ensure maximal proximity of the stents to the collector channel ostia. Our rationale is based on the knowledge that collector channel ostia provide the shortest pathway to aqueous veins and that the collector channels in these areas are more dilated, which collectively can allow for the most efficient outflow [ 68 70 ].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Another explanation could be the differences in surgical techniques. As detailed in our previous studies of the iStent inject, [ 15 18 ] the stents were implanted into the trabecular meshwork, adjacent to the collector channels (identified and marked preoperatively, as described in “ Methods ”), to ensure maximal proximity of the stents to the collector channel ostia. Our rationale is based on the knowledge that collector channel ostia provide the shortest pathway to aqueous veins and that the collector channels in these areas are more dilated, which collectively can allow for the most efficient outflow [ 68 70 ].…”
Section: Discussionmentioning
confidence: 99%
“…The surgical technique has been described in detail elsewhere [ 15 18 ]. In short, two areas with the greatest degree of trabecular meshwork pigmentation or with evidence of focal blood reflux, separated by at least two clock hours, were preoperatively marked at the corneal limbus.…”
Section: Methodsmentioning
confidence: 99%
“…This device has been studied both with and without concomitant cataract extraction, and in studies with up to 5 years of follow-up. [24][25][26][27][28][29][30][31][32][33][34][35][36][37][38][39] Both iStent and iStent inject are implanted ab internally and enhance the physiologic trabecular outflow pathway of aqueous humor, thereby decreasing IOP. Targeting the natural outflow pathway helps avoid the risks of suprachoroidal, bleb-forming, subconjunctival, and/or ab externo procedures.…”
Section: Introductionmentioning
confidence: 99%
“…In vitro perfusion model study did not demonstrate significant difference in outflow facility increase between the two stents. 31 A subgroup analysis by Salimi et al 48 shows no significant difference was found between the two generations in terms of IOPR and medication use in eyes with primary angle closure glaucoma.…”
Section: Discussionmentioning
confidence: 98%