2002
DOI: 10.1016/s1044-0305(02)00347-1
|View full text |Cite
|
Sign up to set email alerts
|

Mass spectrometry—Not just a structural tool: The use of guided ion beam tandem mass spectrometry to determine thermochemistry

Abstract: Guided ion beam tandem mass spectrometry has proved to be a robust tool for the measurement of thermodynamic information. Over the past twenty years, we have elucidated a number of factors necessary to make such thermochemistry accurate. Careful attention must be paid to the reduction of the raw data, ion intensities versus laboratory ion energies, to a more useful form, reaction cross sections versus relative kinetic energy. Analysis of the kinetic energy dependence of cross sections for endothermic reactions… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
186
1

Year Published

2003
2003
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 172 publications
(189 citation statements)
references
References 78 publications
2
186
1
Order By: Relevance
“…The measured ion intensities are converted to absolute cross sections using a Beers' law analysis as described previously [60,61]. Absolute uncertainties in the cross section magnitudes are estimated to be ±20%, which are derived largely from errors in the pressure measurement and the effective length of the interaction region.…”
Section: Data Handlingmentioning
confidence: 99%
“…The measured ion intensities are converted to absolute cross sections using a Beers' law analysis as described previously [60,61]. Absolute uncertainties in the cross section magnitudes are estimated to be ±20%, which are derived largely from errors in the pressure measurement and the effective length of the interaction region.…”
Section: Data Handlingmentioning
confidence: 99%
“…[25,26] describes a number of validation criteria for determining the kinetic energy threshold for CID reactions [27][28][29]. These validation experiments are particularly important here because the present work is done with a commercial triple quadrupole MS built for chemical analysis, not for accurate thermochemical measurements [30 -34].…”
Section: Ms and Cid Of Nitrate Complexes Of Group 1 And 2 Metalsmentioning
confidence: 99%
“…These data are also converted to cross sections by the method described by Armentrout, [26,Eq 7] with 0 ϭ 18, n ϭ 1. 1.8 eV (data for the latter value are not shown).…”
Section: Threshold Kinetic Energy Measurements For Nomentioning
confidence: 99%
“…This stands in contrast to guided ion beam mass spectrometry, wherein these parameters are precisely controlled and thus the resulting data can be used to derive accurate thermochemical quantities. [81,82] Despite these limitations, for the aims of the current work, the experimentally derived dissociation thresholds have provided an excellent means to explore relative trends in bond energies and to test computational predictions. .…”
Section: Dissociation Thresholds Of Alkoxyamine Ionsmentioning
confidence: 99%