2019
DOI: 10.1134/s0965544119100025
|View full text |Cite
|
Sign up to set email alerts
|

Mass Spectrometry in Petroleum Chemistry (Petroleomics) (Review)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
31
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 30 publications
(33 citation statements)
references
References 222 publications
0
31
0
Order By: Relevance
“…Reactions were performed in screw-capped glass test tubes with magnetic stir bars in an air atmosphere unless otherwise stated. Thiols were purchased from commercial sources and checked by 1 H and 13 C NMR spectroscopy prior to use. (IMes)Pd(acac)Cl, but-3-yn-1-yltriphenylphosphonium bromide, and N-(5-hexynyl)phthalimide were synthesized according to described procedures [38][39][40].…”
Section: General Proceduresmentioning
confidence: 99%
See 3 more Smart Citations
“…Reactions were performed in screw-capped glass test tubes with magnetic stir bars in an air atmosphere unless otherwise stated. Thiols were purchased from commercial sources and checked by 1 H and 13 C NMR spectroscopy prior to use. (IMes)Pd(acac)Cl, but-3-yn-1-yltriphenylphosphonium bromide, and N-(5-hexynyl)phthalimide were synthesized according to described procedures [38][39][40].…”
Section: General Proceduresmentioning
confidence: 99%
“…NMR measurements were performed using a Bruker AVANCE 600, Bruker DRX-500, Bruker Fourier 300 spectrometers operating at 600.1 and 500.1, 300.1 and 150.0, and 125.8 and 75.5 MHz for 1 H and 13 C, respectively. The 1 H and 13 C chemical shifts were referenced to internal standards provided by the solvent or relative to TMS as an external standard for spectra in CDCl 3 .…”
Section: General Proceduresmentioning
confidence: 99%
See 2 more Smart Citations
“…Although the coupling of GC with soft ionizations‐MS has been reported in the 1970s, this interesting hyphenation was expanded in the last decade, probably due to the progress in instrument technology. Different soft ionization techniques have been coupled to GC systems in the analysis of petrochemical samples; however, no record seems to be reported by the use of soft ionizations‐MS coupled with GC for the analysis of biofuels and related products [89]. Advantages and drawbacks of the hyphenation between the most common atmospheric pressure ionization‐MS interfaces and GC systems and new developments in source geometry, ion source miniaturization, multipurpose ion source constructions, and comparison with GC‐FID and GC‐EI‐MS detections have been reviewed by Li and co‐workers [90].…”
Section: Ms Detectionmentioning
confidence: 99%