2011
DOI: 10.1002/rcm.5138
|View full text |Cite
|
Sign up to set email alerts
|

Mass spectrometric characteristics and kinetics of iron release in visceral mass of Saccostrea cucullata

Abstract: Ferritins with electrophoretic homogeneity were prepared from the visceral mass of Saccostrea cucullata in batch. The native PAGE approach showed similar electrophoretic mobility among pig pancreatic ferritin, liver ferritin of Dasyatis akajei, and visceral mass ferritin of Saccostrea cucullata. SDS-PAGE indicated that the Saccostrea cucullata visceral ferritin (SCVF) consisted of a single subunit type and had a molecular weight (MW) of approximately 20 kDa, suggesting that the protein shell in SCVF was compos… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
3
0

Year Published

2015
2015
2015
2015

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(3 citation statements)
references
References 38 publications
0
3
0
Order By: Relevance
“…40 Other groups have studied characteristics of the ferritin subunits using mass spectrometric proteomic techniques. [41][42][43] The lack of MS publications on intact ferritin is likely due to the fact that traditional MS techniques for HoloFt could not be utilized because of the high molecular weight and broad size distribution of the assembly. Here we present heavy ion mass 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 7 spectrometry (HIMS) work above 100 kTh utilizing matrix-assisted laser desorption ionization (MALDI) time-of-flight (TOF) MS which incorporates a superconducting tunnel junction (STJ) cryodetector.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…40 Other groups have studied characteristics of the ferritin subunits using mass spectrometric proteomic techniques. [41][42][43] The lack of MS publications on intact ferritin is likely due to the fact that traditional MS techniques for HoloFt could not be utilized because of the high molecular weight and broad size distribution of the assembly. Here we present heavy ion mass 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 7 spectrometry (HIMS) work above 100 kTh utilizing matrix-assisted laser desorption ionization (MALDI) time-of-flight (TOF) MS which incorporates a superconducting tunnel junction (STJ) cryodetector.…”
Section: Introductionmentioning
confidence: 99%
“…In 2006, de Val et al measured the mass of horse ApoFt, made recombinately consisting entirely of the L subunit, to be 491.5 kDa, also by ESI-MS . Other researchers have investigated modifications made to ApoFt/HoloFt in vitro . Hoppler et al. have developed a quantitative method for measuring ferritin-bound iron in plant species utilizing isotope dilution MS .…”
mentioning
confidence: 99%
See 1 more Smart Citation