2014
DOI: 10.1021/ac502583b
|View full text |Cite
|
Sign up to set email alerts
|

Mass Selective Ion Transfer and Accumulation in Ion Trap Arrays

Abstract: The concept and method for mass selective ion transfer and accumulation within quadrupole ion trap arrays have been demonstrated. Proof-of-concept experiments have been performed on two sets of ion trap arrays: (1) a linear ion trap with axial ion ejection plus a linear ion trap with radial ion ejection; (2) a linear ion trap with axial ion ejection plus a linear ion trap with axial ion ejection. In both sets of ion trap arrays, ions trapped in the first ion trap could be mass selectively transferred and accum… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
19
0
1

Year Published

2016
2016
2022
2022

Publication Types

Select...
6
1
1

Relationship

3
5

Authors

Journals

citations
Cited by 25 publications
(20 citation statements)
references
References 52 publications
0
19
0
1
Order By: Relevance
“…Details about the instrument setup could be found in Wang et al [39]. Briefly, a nano electrospray ionization source was used for sample ionization.…”
Section: Ms Instrumentationmentioning
confidence: 99%
“…Details about the instrument setup could be found in Wang et al [39]. Briefly, a nano electrospray ionization source was used for sample ionization.…”
Section: Ms Instrumentationmentioning
confidence: 99%
“…It may be a convenient instrument for studying top-down proteomics to detect intact proteins. Wang et al used the first ion trap to store the injected ions (Wang et al, 2014). The targeted ions were then selectively ejected into the second ion trap.…”
Section: Combination Of Ion Trap and Other Analyzers Ion Trap Arraysmentioning
confidence: 99%
“…For example, ion mobility-mass spectrometry (IM-MS) has been shown to improve sensitivity and selectivity by fractionating mixtures on the basis of ion collisional cross section (CCS).24-26 Other approaches have taken advantage of hybrid mass spectrometry instrumentation to perform ion accumulation in a separate ion trap prior to mass analysis. 27 For example, ion accumulation in a linear octopole ion trap positioned external to a Fourier transform ion cyclotron resonance (FTICR) cell enabled dramatic improvements in sensitivity.28 29 These external accumulation setups have demonstrated limits of detection of 20 zmol of cytochrome c and duty cycles of 100% during electrospray ionization (ESI) experiments.…”
Section: Introductionmentioning
confidence: 99%