Mass Difference Maps and Their Application for the Recalibration of Mass Spectrometric Data in Nontargeted Metabolomics

Abstract: Modern high-resolution mass spectrometry provides the great potential to analyze exact masses of thousands of molecules in one run. In addition, the high instrumental mass accuracy allows for highprecision formula assignments narrowing down tremendously the chemical space of unknown compounds. The adequate values for a mass accuracy are normally achieved by a proper calibration procedure that usually implies using known internal or external standards. This approach might not always be sufficient in cases when … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
23
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
7
1

Relationship

4
4

Authors

Journals

citations
Cited by 17 publications
(24 citation statements)
references
References 25 publications
0
23
0
Order By: Relevance
“…The used reagents, sample preparation, and instrumental parameters are given in Supplementary Table 7. Possible space charge effects were recalibrated by mass difference mapping 44 . The samples were measured over a period of 18 months in randomized order using a representative lager beer as quality control.…”
Section: Fia-fticr-ms Measurementsmentioning
confidence: 99%
“…The used reagents, sample preparation, and instrumental parameters are given in Supplementary Table 7. Possible space charge effects were recalibrated by mass difference mapping 44 . The samples were measured over a period of 18 months in randomized order using a representative lager beer as quality control.…”
Section: Fia-fticr-ms Measurementsmentioning
confidence: 99%
“…Gibbs peaks were removed by Data Analysis automatically. All spectra were exported as tab-separated asc files and loaded into the Kernel Calibrator ( 27 ). A mouse calibrant list was generated manually after first precalibrating representative mouse tissue spectra against fatty acids, followed by isotopic pattern simulation of the most abundant MS features.…”
Section: Methodsmentioning
confidence: 99%
“…Gibbs peaks were removed by Data Analysis automatically. All spectra were exported as tab-separated asc files and loaded into the Kernel Calibrator ( 27 ). m/z calibration was then performed against an in-house repository of human blood plasma metabolites for both cohorts.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Subsequently, we further filter the list of candidate reference ions using a method based on a kernel density estimator (KDE) following a similar procedure to that described in Smirnov et al (Smirnov et al, 2019) If candidate reference peaks for M are represented as points with coordinates , we assume that highly dense connected regions represent the shift trends of M .…”
Section: Methodsmentioning
confidence: 99%