Mass bias stabilization by Mg doping for Si stable isotope analysis by MC-ICP-MS

Abstract: The combined SSB + Mg technique for Si isotope measurements under ‘dry’ plasma conditions provides high tolerances against matrix effects induced by matrix mismatch or contaminant elements.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

4
47
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 31 publications
(51 citation statements)
references
References 24 publications
4
47
0
Order By: Relevance
“…Samples and standard solutions were diluted to 2 ppm Si with 1% HNO 3 and introduced to the Neptune through an APEX‐HF (ESI) desolvating nebulizer. These samples were doped with a matching concentration of Mg for mass‐bias stabilization (Oelze et al, 2016) and to correct the isotopic ratios for internal mass bias (Cardinal et al, 2003). During the second session, we used a NuPlasma II MC‐ICP‐MS (Nu Instruments Ltd) at the Vegacenter in the Natural History Museum, Stockholm.…”
Section: Methodsmentioning
confidence: 99%
“…Samples and standard solutions were diluted to 2 ppm Si with 1% HNO 3 and introduced to the Neptune through an APEX‐HF (ESI) desolvating nebulizer. These samples were doped with a matching concentration of Mg for mass‐bias stabilization (Oelze et al, 2016) and to correct the isotopic ratios for internal mass bias (Cardinal et al, 2003). During the second session, we used a NuPlasma II MC‐ICP‐MS (Nu Instruments Ltd) at the Vegacenter in the Natural History Museum, Stockholm.…”
Section: Methodsmentioning
confidence: 99%
“…δ 30 Si was determined in wet plasma mode on a Neptune Plus Multi Collector Inductively Coupled Plasma Mass Spectrometer (MC-ICPMS) (Thermo Fisher Scientific, Germany) at the ICBM, University of Oldenburg. The measurements were carried out with the standard-sample bracketing method with external normalization by magnesium doping used for correction of the mass bias (Cardinal et al, 2003;Oelze et al, 2016). Isobaric interferences of e.g., nitrogen ( 14 N 2 ) and nitric oxide ( 14 N 16 O) were avoided by medium resolution mode focusing on the left side of the peak shoulder.…”
Section: Silicon Isotope Analysesmentioning
confidence: 99%
“…The final Si solutions as well as the standards (NBS28, diatomite) were diluted to 0.6 ppm Si in an 0.1 M HCl matrix and doped with 0.6 ppm Mg for mass-spectrometry. d 30 Si diatom was assessed on a Neptune MC-ICP-MS (multi collector inductively coupled plasma mass spectrometer) using matrix-matched sample-standard bracketing at the German Research Centre for Geosciences Potsdam (GFZ) following standard protocols (Oelze et al 2016).…”
Section: Diatom Preparation and D 30 Si Diatom Measurementsmentioning
confidence: 99%
“…Typical internal precisions of all samples were B 0.05%. In this lab a long-term precision of 0.14% (expressed as 2SD) was determined, which we use here as our analytical uncertainty estimate, determined through 133 measurements of reference material BHVO-2 (Oelze et al 2016). Signal intensities on each of the isotopes resulting from instrumental background and acid blanks were always \ 1% of sample intensities.…”
Section: Diatom Preparation and D 30 Si Diatom Measurementsmentioning
confidence: 99%