Abstract: The out-of-plane behaviour of the walls as a consequence of an earthquake is the main vulnerability of existing masonry structures. In the case of rigid in compression not tensile resistant material, incremental dynamic analyses may be employed to evaluate the effective strength of a rocking element. When the seismic capacity of the wall is inadequate, retrofit interventions are required to assure an acceptable safety level. Conventional seismic retrofitting techniques on masonry walls influence the seismic pe… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 9 publications
(5 citation statements)
references
References 45 publications
0
5
0
Order By: Relevance
“…One example of composite brick masonry walls with brick, FRP, mesh, and fabric-reinforced cementitious matrix (FRCM) masonry is detailed in [61]. The OoP performance of the retrofitting system consisted of a mechanical coupling between the active confinement of the masonry system of steel straps and CFRP strips clearing up the delamination interruption when the transfer of stresses from the steel straps to the CFRP strips occurs on both sides of a bent beam [62]. The combination of shotcrete and FRCM mesh with carbon FRP strips as a strengthening technique enhances the mechanical and durability performance of composite masonry walls (Figure 4) [63].…”
Section: Classification Of the Strengthening Techniques Of Masonry Wallsmentioning
confidence: 99%
“…One example of composite brick masonry walls with brick, FRP, mesh, and fabric-reinforced cementitious matrix (FRCM) masonry is detailed in [61]. The OoP performance of the retrofitting system consisted of a mechanical coupling between the active confinement of the masonry system of steel straps and CFRP strips clearing up the delamination interruption when the transfer of stresses from the steel straps to the CFRP strips occurs on both sides of a bent beam [62]. The combination of shotcrete and FRCM mesh with carbon FRP strips as a strengthening technique enhances the mechanical and durability performance of composite masonry walls (Figure 4) [63].…”
Section: Classification Of the Strengthening Techniques Of Masonry Wallsmentioning
confidence: 99%
“…The mechanisms of the seismic response of confined masonry buildings for in-and out-of-plane seismic effects were explained thoroughly in the Seismic Design Guide for Low-Rise Confined Masonry Buildings [28]. Some retrofitting interventions might be required to strengthen masonry panels [29,30]. If not properly retrofitted, the repair costs for masonry infilled panels that do not have an adequate seismic strength can be significant [31].…”
Section: Retrofitting Asymmetric Reinforced Concrete Frame Buildings: a Worst-case Scenariomentioning
confidence: 99%
“…The seismic conduct of prefabricated strengthened shear partitions with vertical joints was investigated by Zhang and Wang [17,18], in which shear walls were constructed in a pilot building. Coccia et al [19] studied the overall seismic performance of masonry partitions modified with vertical FRP stiffeners and found that conventional methods of seismic strengthening of masonry partitions have an impact on the seismic performance of the components. Generally, out-ofsurface bending behavior is used for modification.…”
Section: Introductionmentioning