2023
DOI: 10.5194/acp-2022-840
|View full text |Cite
Preprint
|
Sign up to set email alerts
|

Markedly different impacts of primary emissions and secondary aerosol formations on aerosol mixing states revealed by simultaneous measurements of CCNC, V/HTDMA and SP2

Abstract: Abstract. The aerosol mixing state is a crucial physical-chemical property that affects their optical properties and cloud condensation nuclei (CCN) activity. Multiple techniques are commonly employed to determine aerosol mixing states for various applications, and comparisons between these techniques provide insights of the variations in aerosol chemical and physical properties. These techniques include size-resolved CCN activity measurements using a system with CCN counter (CCNC) coupled with a differential … Show more

Help me understand this report
View published versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
1

Relationship

1
0

Authors

Journals

citations
Cited by 1 publication
(2 citation statements)
references
References 55 publications
0
2
0
Order By: Relevance
“…(2023) and Tao, Luo, et al. (2023), mass spectra profiles of resolved factors as well as their correlations with fragment signals are also shown in Figures S3 and S4 in Supporting Information . In addition, RH values of the air used in this research were measured with the utmost precision, utilizing a high‐precision RH and temperature sensor (Vaisala HMP 110), which was placed within the inlet box, as illustrated in Figure S1 in Supporting Information .…”
Section: Field Measurements and Methodsmentioning
confidence: 77%
See 1 more Smart Citation
“…(2023) and Tao, Luo, et al. (2023), mass spectra profiles of resolved factors as well as their correlations with fragment signals are also shown in Figures S3 and S4 in Supporting Information . In addition, RH values of the air used in this research were measured with the utmost precision, utilizing a high‐precision RH and temperature sensor (Vaisala HMP 110), which was placed within the inlet box, as illustrated in Figure S1 in Supporting Information .…”
Section: Field Measurements and Methodsmentioning
confidence: 77%
“…(2023) and Tao, Luo, et al. (2023). A fixed RH (84%) humidified nephelometer system was used to measure aerosol scattering coefficients and bulk aerosol hygroscopicity (Kuang, He, Xu, Zhao, et al., 2020).…”
Section: Field Measurements and Methodsmentioning
confidence: 98%