1991
DOI: 10.1016/0022-3913(91)90408-o
|View full text |Cite
|
Sign up to set email alerts
|

Marginal adaptation of castable ceramic crowns

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

2
87
1
6

Year Published

2004
2004
2017
2017

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 119 publications
(96 citation statements)
references
References 9 publications
2
87
1
6
Order By: Relevance
“…The 90° angled shoulder preparation used has been recommended and tested by several authors with successful results. 2,27,29,30,31 Most authors agreed that preference should be given to rounded axiogingival line angles. 27,32 The main advantage of using artificial abutments is the possibility to make a standardised preparation easier.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…The 90° angled shoulder preparation used has been recommended and tested by several authors with successful results. 2,27,29,30,31 Most authors agreed that preference should be given to rounded axiogingival line angles. 27,32 The main advantage of using artificial abutments is the possibility to make a standardised preparation easier.…”
Section: Discussionmentioning
confidence: 99%
“…Digital microscopes, stereomicroscopes, light microscopes and electron microscopes have been used with various magnifications. [2][3][4][5]10,22,27,29,30,[33][34][35][36] According to Groten et al 28 approximately 50 measurements along the margin of a crown yield clinically relevant information. A consistent estimate for the gap size with an overall impact on the measurement error was typically in a range of ± 8µm (SD).…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…18 Kenar ve iç yüzey uyumun değerlendirilmesi amacıyla yapılan birçok çalışmada ölçüm noktalarının sayısı konusunda, literatürde ortaya konan herhangi bir standart bulunmamaktadır. 9,10,13,14,[20][21][22] Kenar ve iç yüzey uyumun değerlendirilmesi amacıyla ölçümlerin yapılacağı noktaların sayılarının arttırılmasının, istatistiksel olarak standart sapmayı azaltarak, elde edilen sonuçların hem istatistiksel, hem de kliniği yansıtması açısından daha güvenilir olacağı belirtilmiştir. 23 Çalış-mamızda, kenar ve iç yüzey uyumu değerlendirmek için yapılan çalışmalarda kullanılan ölçüm noktaları, sonuçların güvenilirliğini arttıracak şekilde modifiye edilerek belirlendi.…”
Section: Discussionunclassified